Residential Air Conditioning System Integrated with Packed Bed Cool Storage Unit for Promoting Rooftop Solar PV Power Generation

Author:

Muthaiyan Kesavan1,Narayanasamy Rajamani2,Lakshmanan Chidambaram1,Vellaichamy Pandiyarajan3,Ramalingam Velraj2ORCID

Affiliation:

1. Mechanical Engineering, Annamalai University, Annamalai Nagar – 608 002

2. Institute for Energy Studies, Anna University, Chennai - 600 025

3. Department of Chemical Engineering, Anna University, Chennai - 600 025

Abstract

The increase in the share of renewable-based power in the gross power generation in most countries causes significant concerns over the addition of renewable power with the grid, results in stability issues in most developed nations. Energy storage is an emerging technology that is considered the ultimate solution in developing microgrids with distributed renewable power generation. The cool thermal storage plays a vital role in economically promoting renewable power among different storage units. The major objective of the research work is to demonstrate the integration of residential air-conditioning systems with packed bed cool storage units to promote rooftop solar power generation for residential space cooling applications. In order to achieve the said objective, an experimental investigation was made to study the charging/discharging characteristics of a packed bed cool-storage unit combined with a chiller and a cooling coil unit suitable for small capacity air-conditioning applications. The system consists of encapsulated spherical capsules filled with a phase change material blended with distilled water and pseudomonas (nucleating agent) and the heat transfer fluid as a combination of distilled water and Mono-ethylene glycol. A cooling coil unit was connected to the cool-storage tank to transfer cool energy from the storage tank to the space to be cooled when there is a demand. The important parameters, such as instantaneous and cumulative heat transfer during the charging/discharging processes, are presented. The average COP values of the chiller during the charging operation were estimated as 1, 0.93, and 0.89 when the HTF setpoint temperatures were -6°C, -9°C, and -12°C, which shows a decrease in performance as the setpoint temperature decreases. During the discharging process, a cooling load of 2.25 kW is obtained during the first cycle of operation and gradually reduces to 0.3 kW during the sixth cycle of operation. The increase in the HTF temperature during each cycle of operation indicates that the Phase Change Material (PCM) in the balls cannot release the heat as per the demand after a certain period of discharging. Hence, decreasing the internal thermal resistance by suitable measures is essential to achieve uniform heat flux and to operate the system successfully

Publisher

Institute of Research and Community Services Diponegoro University (LPPM UNDIP)

Subject

Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Environmental Engineering

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3