Three-Dimensional Finite Element Analysis Used to Compare Six Different Methods of Syndesmosis Fixation with 3.5- or 4.5-mm Titanium Screws

Author:

Er Mehmet Serhan1,Verim Ozgur2,Altinel Levent1,Tasgetiren Suleyman2

Affiliation:

1. Department of Orthopedics and Traumatology, University of Afyon Kocatepe, School of Medicine, Afyonkarahisar, Turkey.

2. Department of Mechanical Engineering, Faculty of Technology, University of Afyon Kocatepe, Afyonkarahisar, Turkey.

Abstract

Background: Use of thicker and longer (four cortices) screws or of multiple screws seems to be more stable and efficient for syndesmosis fixation. Methods: A three-dimensional finite element model of an ankle was constructed from serial axial sections from an existing two-dimensional computed tomographic image. Constructions of syndesmosis fixation with 3.5-mm single tricortical, 3.5-mm single quadricortical, 3.5-mm double tricortical, 3.5-mm double quadricortical, 4.5-mm single tricortical, and 4.5-mm single quadricortical screws were performed on this model. Physiologic loads approximating those during stance phase normal walking were applied to this ankle system. Stress values on the screws using the six fixation methods were compared. Results: The highest maximum stress was determined over 3.5-mm cortical screws applied as single quadricortical, and the lowest maximum stress was determined over the 4.5-mm cortical screw applied as single quadricortical. Stress on the 3.5-mm single screw with quadricortical application was found to be higher than that with tricortical application and also compared with the 4.5-mm quadricortical screw application. Differences between the 4.5-mm single tricortical and quadricortical screws and between the 3.5-mm single tricortical and 3.5-mm double tricortical screw applications were not significant. Conclusions: Quadricortical application of 3.5-mm single screws and tricortical application of 3.5-mm double cortical screws are not good choices for syndesmosis fixation. If the plan is tricortical application, a 3.5-mm single cortical screw is adequate. If quadricortical application of syndesmosis fixation is planned, a 4.5-mm cortical screw should be used. (J Am Podiatr Med Assoc 103(3): 174–180, 2013)

Publisher

American Podiatric Medical Association

Subject

General Medicine

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3