Comparison of Biomechanical Effects of Different Configurations of Kirschner Wires on the Epiphyseal Plate and Stability in a Salter-Harris Type 2 Distal Femoral Fracture Model

Author:

Inal Sermet1,Gok Kadir2,Gok Arif3,Pinar Ahmet Murat4,Inal Canan5

Affiliation:

1. Department of Orthopaedic Surgery, School of Medicine, Campus of Evliya Celebi, Kutahya Health Sciences University, Kutahya, Turkey.

2. Department of Mechanical and Manufacturing Engineering, Hasan Ferdi, Turgutlu Technology Faculty, Celal Bayar University, Manisa, Turkey.

3. Department of Mechanical Engineering, Technology Faculty, Amasya University, Amasya, Turkey.

4. Department of Mechanical and Manufacturing Engineering, Technology Faculty, Parmukkale University, Denizli, Turkey.

5. Department of Anesthesiology and Reanimation, Kutahya Education and Research Hospital, Kutahya, Turkey.

Abstract

Background: We sought to investigate the different configurations of Kirschner wires used in distal femur Salter-Harris (SH) type 2 epiphyseal fracture for stabilization after reduction under axial, rotational, and bending forces and to define the biomechanical effects on the epiphyseal plate and the fracture line and decide which was more advantageous. Methods: The SH type 2 fracture was modeled using design software for four different configurations: cross, cross-parallel, parallel medial, and parallel lateral with two Kirschner wires, and computer-aided numerical analyses of the different configurations after reduction were performed using the finite element method. For each configuration, the mesh process, loading condition (axial, bending, and rotational), boundary conditions, and material models were applied in finite element software, and growth cartilage and von Mises stress values occurring around the Kirschner wire groove were calculated. Results: In growth cartilage, the stresses were highest in the parallel lateral configuration and lowest in the cross configuration. In Kirschner wires, the stresses were highest in the cross configuration and lowest in the cross-parallel and parallel lateral configurations. In the groove between the growth cartilage and the Kirschner wire interface, the stresses were highest in the parallel lateral configuration and lowest in the cross configuration. Conclusions: The results showed that the cross configuration is advantageous in fixation. In addition, in the SH type 2 epiphyseal fracture, we believe that the fixation shape should not be applied in the lateral configuration.

Publisher

American Podiatric Medical Association

Subject

General Medicine

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3