Intraocular pressure response to airway management: Comparison between LMA Supreme® and C-MAC® videolaryngoscope in day care surgery

Author:

Kaur Haramritpal,Singh Gurpreet,Singh Jaipreet,Dhawan Munish,Singh Amandeep,. Kaur

Abstract

Background: Airway maintenance procedures during anesthesia are usually associated with a rise in intraocular pressure (IOP). This is an important issue especially in vulnerable patients. In the present study we compared the rise in IOP with two different group of airway devices i.e. Laryngeal mask airway Supreme (LMA-S) and endotracheal intubation (ETT) using C-MAC® videolaryngoscope (VLS). Methodology: The present study was conducted on 100 adult patients of ages >18 yrs, of either sex, belonging to American Society of Anesthesiologist (ASA) I and II, scheduled to undergo non-ophthalmic elective surgery under general anesthesia. Patients were divided into two equal groups of 50 each, Group A and Group B. In group A (n = 50), lubricated appropriate sized LMA-S was inserted and in Group B (n=50), lubricated appropriate sized ETT was inserted by an anesthesiologist using VLS. IOP was measured in right eye just before insertion of device and subsequently at 1 min, 3 min, 5 min and 10 min after insertion of device. Hemodynamic parameters were recorded along with IOP measurement. Results: Both the groups were comparable regarding demographic data (p > 0.05), ASA grade (p = 0.069), and Mallampati grade (MPG) (p = 0.646). Airway establishment time (p = 0.011) was significantly less with C-MAC VLS. IOP were comparable at all measurement times, e.g., 1 min (p = 0.216), 3 min (p = 0.093), 5 min (p = 0.859) and 10 min (p = 0.060) after insertion of each device. Hemodynamic parameters measured were also comparable between two groups (p > 0.05). Conclusion: Both LMA Supreme and intubation using C-MAC® videolaryngoscope are safe regarding rise in intraocular pressure. Both methods can be safely used for airway management in suitable patients. Key words: Airway; Anesthesia; Intraocular pressure; LMA; Endotracheal intubation Citation: Kaur H, Singh G, Singh J, Kaur, Dhawan M, Singh A. Intraocular pressure response to airway management: Comparison between LMA Supreme and C-MAC® videolaryngoscope in day care surgery. Anaesth. pain intensive care 2020;24(6):__ Received: 27 January 2020, Revised: 12 May 2020, Reviewed: 25 October 2020, Accepted: 27 October 2020

Publisher

Aga Khan University Hospital

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3