Bispectral index monitoring in spinal anesthesia with sedation can prevent dexmedetomidine related bradycardia: a randomized clinical trial

Author:

Kim Jiwook,Kim Hui Young,Yun Minsu,Lee Jeongyeop,Kim Joo-Duck,Kang Donghee

Abstract

Background: An unintentional large dose of dexmedetomidine during sedation can lead to increased side effects such as bradycardia and hypotension. We investigated whether the frequency of bradycardia in patients undergoing surgery under spinal anesthesia and sedation with dexmedetomidine was effected if bispectral index (BIS) was used to monitor the sedation. Methodology: Fifty patients between 20 and 60 y of age, who underwent spinal anesthesia, were included in this study. The patients were divided into two groups (control and BIS groups). Patients in the control group were administered a loading dose of 1 μg/kg dexmedetomidine for the first 10 min without BIS monitoring, followed by a maintenance dose of 0.2 μg/kg/h. Patients in the BIS group received a loading dose of 1 μg/kg dexmedetomidine for the first 10 min. The maintenance dose in this group was administered at the discretion of the anesthesiologist to maintain the BIS score between 50 and 70. The baseline heart rate (HR), lowest HR, and the difference between baseline and the lowest HR were calculated. Results: The baseline HR was 74.4 ± 11.0 beats per minute (bpm) and 80.9 ± 16.0 bpm, in the control and BIS groups respectively (p = 0.098). The difference between the baseline and lowest HR in the control and BIS groups was 19.4 ± 7.6 bpm and 25.5 ± 8.8 bpm, respectively (p = 0.011). Low baseline HR was positively correlated with a reduced lowest HR. Conclusions: The frequency of bradycardia during sedation with dexmedetomidine decreased with BIS monitoring. Patients with a low baseline HR were more likely to develop bradycardia during sedation with dexmedetomidine. Therefore, BIS monitoring may be helpful in patients with low baseline HR. Key words: Bispectral index monitor; Dexmedetomidine; heart rate; spinal anesthesia Citation: Kim J, Kim HY, Yun M, Lee J, Kim JD, Kang D. Bispectral index monitoring during sedation with dexmedetomidine in spinal anesthesia prevents bradycardia: a randomized clinical trial. Anaesth. pain intensive care 2021;26(1):14-19 ; DOI: 10.35975/apic.v26i1.1760

Publisher

Aga Khan University Hospital

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3