I-gel supraglottic airway use is efficient and safe during minimal flow anesthesia with volume controlled ventilation - a randomized controlled trial

Author:

Khan Asma,Kapoor Mukul Chandra,Garg Shaloo,Puri Archana,Sinha Ashish

Abstract

Background: A fear of potential gas leak limits the wide spread use of minimal flow anesthesia with supraglottic airway devices. Second generation supraglottic airway devices have been claimed to be come with good airway seal. I-gel is one of these and it has been extensively evaluated for spontaneous as well as assisted ventilation. We conducted this study to evaluate its use with low flow anesthesia and volume controlled ventilation. Methodology: In a prospective randomized controlled trial, 50 patients undergoing laparoscopic surgeries for less than 2 h duration were administered general anesthesia, with controlled ventilation, using either endotracheal tube or an I-gel for airway control. The total fresh gas flow was gradually reduced until it was 400 mL/min. Patients were monitored for evidence of loss of respiratory gas volume in the breathing circuit and other parameters for ventilation failure. Results: Ventilation could be maintained at a fresh gas flow of 400 mL/min, without clinical or volumetric evidence of gas leak in all patients in the two groups. Two patients in the I-gel group had intraoperative gas leak leading to ventilator failure alarm but the same was corrected by repositioning of the head. The vital signs, peak airway pressure, end-tidal carbon dioxide, set tidal volume and expired tidal volumes were statistically similar in the two groups. Conclusion: I-gel supraglottic airway can be safely and efficiently used for laparoscopic surgery using minimal flow anesthesia and volume controlled ventilation. Citation: Khan A, Kapoor MC, Garg S, Puri A, Sinha A. I-gel supraglottic airway use is efficient and safe during minimal flow anesthesia with volume controlled ventilation - a randomized controlled trial. Anaesth pain intensive care 2020;24(1):__ Abbreviations: Supraglottic airway device – SAD; Volume controlled ventilation – VCV; Pressure controlled ventilation – PCV; Endotracheal tube – ETT; Laryngeal Mask Airway - LMA   DOI: https://doi.org/10.35975/apic.v24i1. Received – 11 June 2019; Reviewed – 20, 23 October 2019; Revised – 31 January 2020; Second Review – 2, 7 January 2020; Accepted – 02 February 2020;

Publisher

Aga Khan University Hospital

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3