Intrarater reliability of cervical range of motion device in measuring cervical active range of motion in patients with chronic neck pain and respiratory dysfunction

Author:

Anwar Sahreen,Arsalan Syed Asadullah,Zafar Humayun,Ahmad Ashfaq,Gillani Syed Amir,Hanif Asif

Abstract

Methodology: We enrolled 30 patients (14 males and 16 females) with chronic neck pain and respiratory dysfunction fulfilling inclusion criteria. Two trials of CAROM measurement for flexion, extension, left and right lateral flexion and left and right rotation were performed, with a gap of one week to measure test retest reliability of CROM device. Intraclass correlation coefficient (ICC), standard errors of measurement (SEM) and minimal detectable change (MDC) were calculated to test the intrarater reliability. Results: Intrarater reliability of repeated measurements of CAROM using the CROM device was found to be good. The ICC values ranged between 0.88-0.97 for flexion, 0.93-0.98 for extension, 0.92-0.98 for right lateral flexion,0.93-0.98 for left lateral flexion. For right rotation it was 0.88-0.97, for left lateral rotation it was 0.95-0.99. The standard error of measurement for these movements ranged from 1.5° to 2.9°. Minimal detectable change ranged from 3.5°for extension to 6.8°for left lateral flexion. Conclusion: Cervical range of motion device is a reliable tool for measuring cervical active range of motion in patients simultaneously suffering from chronic neck pain and respiratory dysfunction. Abbreviations: CAROM - cervical active range of motion; CROM - cervical range of motion; ICC - Intraclass correlation coefficient; SEM - standard errors of measurement; MDC - minimal detectable change Key words: Adult; Exercise Therapy / methods; Female; Humans; Male; Neck Pain / physiopathology; Neck Pain / therapy; Pain Measurement; Pulmonary function; Range of Motion, Articular; Reliability Citation: Anwar S, Arsalan SA, Zafar H, Ahmad A, Gillani SA, Hanif A. Intrarater reliability of cervical range of motion device in measuring cervical active range of motion in patients with chronic neck pain and respiratory dysfunction. Anaesth. pain intensive care 2022;26(4):503-509; DOI: 10.35975/apic.v26i4.1957 Received: September 29, 2021; Reviewed: April 21, 2022; Accepted: May 10, 2022

Publisher

Aga Khan University Hospital

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3