A Simple Radiological Technique for Demonstration of Incorrect Positioning of a Foley Catheter with Balloon Inflated in the Urethra of a Male Spinal Cord Injury Patient

Author:

Vaidyanathan Subramanian1,Hughes Peter L.2,Soni Bakul M.1

Affiliation:

1. Regional Spinal Injuries Centre, Southport, Merseyside, UK

2. District General Hospital, Southport, Merseyside, UK

Abstract

In a male patient with cervical spinal cord injury, the urinary bladder may go into spasm when a urethral catheter is removed and a new Foley catheter is inserted. Before the balloon is inflated, the spastic bladder may push the Foley catheter out or the catheter may slip out of a small-capacity bladder. An inexperienced health professional may inflate the balloon of a Foley catheter in the urethra without realizing that the balloon segment of the catheter is lying in the urethra instead of the urinary bladder. When a Foley balloon is inflated in the urethra, a tetraplegic patient is likely to develop autonomic dysreflexia. This is a medical emergency and requires urgent treatment. Before the incorrectly placed Foley catheter is removed, it is important to document whether the balloon has been inflated in the urinary bladder or not. The clinician should first use the always available tools of observation and palpation at the bedside without delays of transportation. A misplaced balloon will often be evident by a long catheter sign, indicating excessive catheter remaining outside the patient. Radiological diagnosis is not frequently required and, when needed, should employ the technique most readily available, which might be a body and pelvic CT without intravenous contrast. An alternative radiological technique to demonstrate the position of the balloon of the Foley catheter is described. Three milliliters of nonionic X-ray contrast medium, Ioversol (OPTIRAY 300), is injected through the side channel of the Foley catheter, which is used for inflating the balloon. Then, with a catheter-tip syringe, 30 ml of sterile Ioversol is injected through the main lumen of the Foley catheter. Immediately thereafter, an X-ray of the pelvis (including perineum) is taken. By this technique, both the urinary bladder and balloon of the Foley catheter are visualized by the X-ray contrast medium. When a Foley catheter has been inserted correctly, the balloon of the Foley catheter should be located within the urinary bladder, but when the Foley catheter is misplaced with the balloon inflated in the urethra, a round opaque shadow of the Foley balloon is seen separately below the urinary bladder. This radiological study takes only a few minutes to perform, can be carried out bedside with a mobile X-ray machine, and does not require special expertise or preparations, unlike transrectal ultrasonography. When a Foley balloon is inflated in the urethra, abdominal ultrasonography will show an absence of the Foley balloon within the bladder. The technique described above aids in positive demonstration of a Foley balloon lying outside the urinary bladder. Such documentation proves valuable in planning future treatment, education of health professionals, and settlement of malpractice claims.

Publisher

Hindawi Limited

Subject

General Environmental Science,General Biochemistry, Genetics and Molecular Biology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3