Background. The ceramic based on lanthanum zirconate is characterized by optimal mechanical characteristics, low corrosion potential and the absence of cytotoxicity. Thus, the possibility of its use as bone substituting material is currently studied.The purpose of the studywas to determine the mechanical, morphological and x-ray spectral characteristics of bone tissue after implantation of ceramic material based on lanthanum zirconate.Materials and methods. The experiment was conducted on 27 female guinea pigs of a single line, divided into 3 groups of 9 animals each. In the main group (LZ), lanthanum zirconate rods were implanted. In the comparison group (b-TCP), fixation was performed with b-tricalcium phosphate rods. In the native control group (NC) no surgical procedures were performed. A fracture was created in distal metadiaphysis area of femur using open osteoclasia. Animals were hatched 4, 10, and 25 weeks after the start of the experiment. Bone tissue features were studied in the perifocal region. The following methods were used: uniaxial compression, scanning electron microscopy (SEM), energy dispersive x-ray microanalysis (EDxMA). The statistical analysis was performed using the Mann-Whitney test.Results. The architectonics of the newly formed bone in the LZ group appeared as a developed lacunar tubular network. The structural components of the extracellular matrix were oriented along the bone functional load vectors. The Ca/P ratio in the periimplant region of the bone in the LZ group was significantly higher than in the b-TCP and NC groups. This may indicate a high strength of the newly formed bone. Mechanical testing showed that the strength and performance of the system of “lanthanum zirconate – bone” under uniaxial compression exceeded the similar indicators in the b-TCP group.Conclusion. The synthesized new material based on lanthanum zirconate seems promising for use in traumatology and orthopedics. Although, additional studies are needed to optimize these implants integration into bone tissue.
Reference32 articles.
1. Gilev M.V., Zaytsev D.V., Izmodenova M.yu., Kiseleva D.V., Volokitina E.A. The influence of bone substitute material on mechanical properties of trabecular bone inaugmentation of intra-articular impression fractures. Experimental study. Genij Ortopedii. 2018;24(4): 492-499. doi:10.18019/1028-4427-2018-24-4-492-499.
2. Gilev M.V., Zaitsev D.V., Izmodenova M.y., Kiseleva D.V., Silaev V.I. Comparative characteristic of the methods of certification of deformed microstructure of trabecular bone tissue. R J Biomech. 2019;23(2):202-208. (In Russian). doi: 10.15593/RJBiomech/2019.2.06.
3. Dubrov V.E., Shcherbakov I.M., Saprykina K.A., Kuzkin I.A., Zyuzin D.A., yashin D.V. [Mathematical Modeling of the «Bone-Fixator» System during the Treatment of Intertrochanteric Fractures]. Travmatologiya i ortopediya Rossii [Traumatology and Orthopedics of Russia]. 2019;25(1):113-121. (In Russian). doi: 10.21823/2311-2905-2019-25-1-113-121.
4. Depprich R., Naujoks C., Ommerborn M., Schwarz F., Kübler N.R., Handschel J. Current findings regarding zirconia implants. Clin Implant Dent Relat Res. 2014;16(1): 124-137. doi: 10.1111/j.1708-8208.2012.00454.x.
5. Bankoğlu Güngör M., Aydın C., yılmaz H., Gül E.B. An overview of zirconia dental implants: basic properties and clinical application of three cases. J Oral Implantol. 2014;40(4):485-494. doi: 10.1563/AAID-JOI-D-12-00109.
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献