Relevance. The altered hip anatomy makes total hip arthroplasty in patients with hip dysplasia a difficult and non-standard task. The acetabulum is deformed with femoral head in subluxation or dislocation. The most important task of surgery is to restore the anatomical position of the hip center of rotation.The study purpose — to evaluate the early results of hip arthroplasty with individual augments in the patients with hip dysplasia.Materials and Methods. Since 2017, nine patients with hip dysplasia have undergone surgery using individually printed augments. All patients were women with average age 51.3±14.5 years (23 to 67). The mean follow-up was 14.3±5.2 months (8 to 20). Patients were evaluated using follow-up X-rays, a visual analogue scale (VAS), Harris Hip Score (HHS), and Western Ontario and McMaster Universities Arthritis Index (WOMAC).Results. There was no a single case of endoprosthesis dislocation, loosening of components, prosthetic infection or revision surgery in the analyzed group of patients. The planned sizes of the acetabular components were equal to the placed in 7 cases (77.8%). In two cases (22.2%), the acetabular components were 2 mm larger because the surgeon wanted a greater degree of press-fit fixation. The restoration of the anatomical position of the acetabular component was noted. Before the surgery, the femoral head was on average 22.7±11.7 mm (10 to 43 mm) higher. After the surgery, the level of the acetabular component was on average only 0.75±2.1 mm (1.7 to 5 mm), p = 0.008. Also, there were a decrease in pain and quality of life improvement by VAS from 6.78±1.39 before surgery to 2.22±1.09 at follow-up (p = 0.007), HHS increase from 30.5±18. 1 to 77.59±14.26 (p = 0.008), and WOMAC decrease from 73.3±14.1 to 18.22±8.2 (p = 0.008).Conclusion. The individually printed augments have shown high efficacy for restoration of the anatomical center of rotation and good early results in the patients with hip dysplasia undergone hip arthroplasty.

Publisher

ECO-Vector LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3