Cage Subsidence after Surgery on the Anterior Part of the Subaxial Cervical Spine: a Monocentric Prospective Clinical Study with a 3-Year Follow-Up

Author:

Kolesov S. V.1,Kazmin A. I.1,Skorina I. V.1,Shvets V. V.1,Sazhnev M. L.1,Panteleev A. A.1,Pereverzev V. S.1,Kolbovski D. A.2

Affiliation:

1. Priorov National Medical Research Center of Traumatology and Ortopaedics

2. Priorov National Medical Research Center of Traumatology and Ortopaedics; Russian Medical Academy of Continuous Professional Education

Abstract

The choice of an implant for vertebra body defect replacement in corpectomy for traumatic lesions remains a point of discussion among spinal surgeons. Nanostructured carbon cages are promising for use in spinal surgery.The purpose of this study was to determine the rate and degree of cage subsidence in the patients with traumatic lesions of the cervical spine undergone a single-level anterior corpectomy in the subaxial part of the cervical spine with reconstruction using a carbon or titanium cage. Materials and Methods. A prospective study included 47 patients undergone a single-level corpectomy of the cervical spine due to traumatic injury. Two groups were formed by adaptive randomization: group I with the patients with carbon cages (n = 23), and group II with the patients with titanium cages (n = 24). The evaluation of cages subsidence and stability was carried by X-rays and CT before and after surgery. The quality of life before and after the surgery was evaluated using NDI and VAS questionnaires.Results. According to the questionnaires, the absolute majority of the patients in both groups showed a statistically significant improvement of quality of life in the postoperative period (p<0.01). The first signs of implant subsidence were noted 3 months after surgery in group II. There were none of such cases in group I. The final result of the subsidence at the end of the follow-up comprised: for group I 0.6±0.4 mm, for group II 3.1±1.4 mm (p = 0.023). In group II, the bone block between bone tissue and the cage was recorded in 30% of patients (p = 0.037), in group I, the bone block was not formed. At the same time, according to the functional X-ray data, there were no signs of carbon cages instability in group I. None of the patients in groups I and II required revision surgery due to complications associated with cages placement.Conclusion. The outcomes of carbon nanostructure cages placement as bodyreplacing implants in the cervical spine were not inferior to the outcomes of titanium mesh cages using. In group I, the carbon cages subsidence was significantly lower than in group II with titanium cages. The bone block was not formed in the case of carbon cages. It is worth noting that the carbon structure of the cages allowed the radiological diagnostics of the operated segment without artifacts formation.

Publisher

ECO-Vector LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3