Copper-Coated Spacer for Total Femoral Replacement in Recurrent Periprosthetic Joint Infection: A Case Report

Author:

Белокобылов А. А.ORCID,Batpenov N. D.,Balgazarov S. S.ORCID,Serikbayev V. D.ORCID,Krikliviy A. A.ORCID,Plotnikov S. V.ORCID,Turlybekuly A.ORCID,Rimashevskiy D. V.ORCID

Abstract

Background. There are few cases of entire femur modular replacement with hip and knee joints in patients with periprosthetic joint infection (PJI) in literature. They report encouraging results in patients of elderly and senile age. We present case of a copper-coated femoral spacer implantation to 50-year-old patient with multiple PJI episodes and osteomyelitis of the entire femur.Clinical presentation. A 40-year-old male patient after resection of the proximal part of the right femur for fibrotic osteodysplasia underwent total hip arthroplasty with replacement of 15 cm of the femur. In December 2010 (20 months after implantation), instability of the femoral component developed, revision arthroplasty was performed with stem recementation. After 4 months, sinus tract formed in the area of the postoperative scar. After another 4 months, the head of the prosthesis was dislocated. In September 2011, the endoprosthesis components were removed and a unipolar cement spacer was implanted. The limb immobilized in a hip spica cast. Methicillin-sensitive S. epidermidis (MSSE) was detected in the preoperative joint aspiration puncture and periprosthetic tissues. After 3 months (December 2011), patient underwent revision total hip arthroplasty (25 cm defect was replaced). 5 years of PJI remission followed. In November 2016 after PJI recurrence the endoprosthesis was removed, and an articulating spacer was implanted. P. aeruginosa was detected in periprosthetic tissues. For the past 2.5 years there were periodically sinus tracts formations. In August of 2019 spacer’s migration resulted in an intercondylar fracture of the right femur. In September 2019, spacer was removed, and MSSE was detected in the surrounding tissues. An articulating cement spacer based on an oncological modular total femur coppercoated endoprosthesis was implanted. At each control examination during the year copper concentration in blood serum was determined, it did not exceed 900–1200 mcg/l. No local or systemic side effects were detected. The patient started working 3 months after surgery. After 6 months poor functioning sinus tract formed in the postoperative scar area in the lower third of the thigh. 1.5 years after the operation, the functional condition is satisfactory.Conclusion. The use of the copper-coated spacer based on modular total femur endoprosthesis with hip and knee joints in a patient with multiple PJI allowed to improve the function of the limb and reduce the severity of the infectious process. No local or systemic toxic effects of copper were detected.

Publisher

ECO-Vector LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3