Long-Term Results of Total Hip Arthroplasty with RM Classic Cups

Author:

Danilyak V. V.1,Klyuchevsky V. V.2,Molodov M. A.2,Goryunov E. V.3,Marchenkova K. V.3

Affiliation:

1. Yaroslavl Regional Clinical Hospital of War Veterans — International Center “Healthy Longevity”

2. Yaroslavl Regional Clinical Hospital of War Veterans – International Center “Healthy Longevity”

3. Yaroslavl State Medical University

Abstract

Relevance. The RM Classic monoblock titanium-coated polyethylene cup is widely used in the total hip arthroplasty. However, so far in Russia there has been no analysis of follow-up over 10 years for a limited number of patients in a single hospital. The aim of the study was to evaluate the long-term outcomes of total hip replacement with RM Classic acetabular component. Materials and Methods. The outcomes of 328 total hip arthroplasties (289 patients operated in the period from 1997 to 2007) with RM Classic cups were evaluated in a monocentral retrospective clinical study. The average follow-up period was 14.4 years. Revision procedure due to aseptic loosening, polyethylene wear or osteolysis was considered as the end point of the study. Results. 9 revisions during the short and medium follow-up periods (up to 10 years) were associated with malpositioning of RM Classic components and errors in surgical technique. The indications for later revision THA (19 cases) were polyethylene wear and aseptic loosening. Only in one case they were combined with pelvic bone osteolysis with the formation of III a defect according to W.G. Paprosky classification. Within 15 years the Kaplan-Meier survivorship of RM Classic cup was 92.5%. There was a statistically significant difference of the survival curves in the ceramic-on-poly against metal-on-poly bearings: 94.9% and 79.4%, respectively. The average Harris Hip Score was 88.6. Conclusion. RM Classic uncemented monoblock cup has proven its high efficiency and survival in 15 years follow-up period and over.

Publisher

ECO-Vector LLC

Reference27 articles.

1. Mathys R. History — how the successful story of the RMClassic Cup started. Horne G. (ed.). Hip-joint surgery: the RM cup : long-term experience with an elastic monobloc acetabular implant. Hamburg : Einhorn-Presse; 2008. p. 11-15.

2. Mathys R. The RM cup: from the idea to the product. In: Bergmann E.G. (ed.). Hip-Joint Surgery: the RM Cup : monograph of a coated acetabular implant. Reinbek : Einhorn-Presse; 1998. p. 10-16.

3. Kini S.G., Anwar R., Bruce W., Walker P. Modular versus monoblock cementless acetabular cups in primary total hip arthroplasty — a review. Int J Orthop. 2014;1(3): 93-99. doi: 10.6051/j.issn.2311-5106.2014.01.22

4. Witzel U. Distribution of stress in a hemispherical RM cup and its bony bed. In: Horne G. (ed.). Hip-joint surgery : the RM cup : long-term experience with an elastic monobloc acetabular implant. Hamburg : Einhorn-Presse; 2008. p. 29-41.

5. Heirholzer G., Jukema G.N. The uncemented Robert Mathys cup. In: Horne G. (ed.). Hip-joint surgery : the RM cup: long-term experience with an elastic monobloc acetabular implant. Hamburg : Einhorn-Presse; 2008. p. 62-73.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3