Results of application of the IRIS dental implants with the surface modified by the method of plasma electrolytic oxidation

Author:

Murzabekov A. I.1,Muraev A. A.2ORCID,Mukhametshin R. F.2ORCID,Kim E. V.2ORCID,Ivanov S. Yu.3ORCID,Klimenkov V. A.2

Affiliation:

1. Patrice Lumumba Peoples’ Friendship University of Russia; Central Clinical Hospital of the Administrative directorate of the President of the Russian Federation

2. Patrice Lumumba Peoples’ Friendship University of Russia

3. Patrice Lumumba Peoples’ Friendship University of Russia; I.M. Sechenov First Moscow State Medical University

Abstract

Surface modifications of dental implants to provide optimal conditions for osseointegration remains an urgent task in modern dental implantology. A few publications demonstrate that the surface of the dental implants modified by plasma electrolytic oxidation (PEO) possess a combination of several important features that promote osteointegration: optimal micro roughness within 1-7 microns, high chemical purity, and mechanical strength [8,20].The aim. To evaluate the clinical efficacy of IRIS implants with a new surface modified by the PEO method (hereinafter referred to as IRIS PEO).Materials and methods. Based on the Patrice Lumumba RUDN Medical Center and the Center of Medical Care for Dental Diseases, FGBU «Central Clinical Hospital with Polyclinic» of the Presidential Affairs Department of the Russian Federation, 60 patients aged 27 to 52 years with partial tooth loss were examined and treated. The patients received 1 IRIS-PEO implant each on the upper or lower jaw. All implants were placed with the force from 35 to 50 N/cm2, with gingiva shapers. Prosthetics were performed after 2 months on the lower jaw and after 4 months on the upper jaw. Before taking impressions, the stability of implants was measured using the Penguin RFA (Integration Diagnostic Sweden AB, Sweden). One year after prosthetics, the neck resorption of the implants was evaluated.Results. Because of the treatment, all prosthetic constructions met the functional and aesthetic requirements. The stability indices of implants in ISQ units on the upper jaw averaged 75±3.4, on the lower jaw 79±2.4. Bone resorption in the implants’ neck area 1 year after the end of the treatment was not observed. The pilot clinical study of the IRIS-PEO implants allowed to optimize the terms of rehabilitation and to obtain high functional and esthetic result in the treatment of patients with tooth loss.Conclusions. Pilot clinical implementation of the implants of the IRIS system with the surface modified by plasma electrolytic oxidation demonstrated the possibility of open management of the implants with the gingiva shaper, to carry out prosthetics in 2 months on the lower jaw and 4 months on the upper jaw. No neck resorption was observed one year after prosthetics.

Publisher

Alfmed LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3