Reference values of activated partial thromboplastin time, Quick`s value, INR, thrombin time, fibrinogen, antithrombin and II, V, VII, VIII, IX, X, XI and XII coagulation factors determined with automated Sysmex CS-2000i analyzer

Author:

Gorgidze L. А.1ORCID,Mamleeva S. Yu.1ORCID,Pimenov М. S.2,Smirnova А. V.2,Bulgakov А. V.1,Galstyan G. М.1ORCID

Affiliation:

1. National Medical Research Centre for Hematology

2. Sysmex Rus Co.

Abstract

The article defines reference values for activated partial thromboplastin time, Quick’s value, INR, thrombin time, fibrinogen, antithrombin and II, V, VII, VIII, IX, X, XI and XII coagulation factors, according to existing standards on the automated Sysmex CS‑2000i analyzer.The aim of the study. To determine reference values for routine and specific parameters of the hemostasis, which may vary depending on the type of analyzer and utilized reagents.Materials and methods. After receiving informed consent from donors for medical survey and blood donation, blood samples were obtained from 100 healthy donors: 64 (64%) males и 36 (36%) females. We established reference values with the Sysmex CS‑2000i (Sysmex, Japan) hemostasis analyzer and reagents from Siemens (Siemens Healthcare, Germany).Results. The data obtained were compared with the literature data and the data presented in the instructions for the reagents used. The results obtained for activated partial thromboplastin time (23.59–35.69 sec), fibrinogen (1.67–3.59 g/l) and antithrombin (67.65–114.89%) are comparable to the available data. There are no data on other studied parameters of hemostasis for the Sysmex CS‑2000i analyzer and the reagents used in the work. The obtained reference intervals are consistent with the recommendations of the manufacturer.Conclusions. Reference values vary significantly depending on the analytical systems and reagent kits used, which confirms the need for local derivation or validation of reference intervals for each specific analytical system and in each laboratory.

Publisher

Alfmed LLC

Subject

Materials Chemistry,Economics and Econometrics,Media Technology,Forestry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3