Assessment of the body composition of basketball players by anthropometry and bioimpedancemetry methods – comparison of the results of calculated and two hardware methods

Author:

Vybornaya К. V.1ORCID,Semenov М. М.2ORCID,Radzhabkadiev R. M.1ORCID,Krikun E. N.3ORCID,Klochkova S. V.4ORCID,Nikityuk D. B.5ORCID

Affiliation:

1. Federal Research Center for Nutrition, Biotechnology and Food Safety

2. Center of biomedical technologies, North-Caucasian Federal Research-Clinical Center of FMBA of Russia

3. Moscow State Academy of Physical Culture

4. RUDN University

5. Federal Research Center for Nutrition, Biotechnology and Food Safety; RUDN University; I.M. Sechenov First Moscow State Medical University

Abstract

Standardization of methods for assessing body composition is an extremely relevant topic, especially when analyzing the long-term training of athletes. Evaluation of the results of measuring body composition using the method of classical anthropometry in comparison with the hardware method of bioimpedanceometry is relevant, because Measurement results from these techniques often vary, and it is important for practitioners and trainers to be aware of these differences.The aim of the study was to ompare the results of assessing the body composition of basketball players obtained using the calculation and two hardware methods.Materials and methods. The survey involved 25 students-basketball players (age 20.3±1.7 years). Body composition was assessed by three methods: calculation – according to the formulas of J. Mateyk, hardware – using the body composition analyzer ABC‑01 (LLC STC «MEDASS», Russia), hardware – using the basic multi-frequency portable body composition analyzer ACCUNIQ BC310 (SELVAS Healthcare Inc., Daejeon, South Korea). Statistica software was used for statistical calculations and plotting. The significance of differences between independent groups was determined using the nonparametric Mann – Whitney test (U-test). Distribution normality was assessed using the Shapiro – Wilk test. The nonparametric Wilcoxon test was used to compare dependent samples. Correlation analysis – according to Bland – Altman.Results and discussion. The calculation method based on anthropometry gives significantly greater results in terms of skeletal muscle mass; in terms of basal metabolism, ACCUNIQ gives the highest values, Medass – the smallest, anthropometry method – the average between the results obtained by two hardware methods. Correlation analysis showed that when determining lean body mass, the closest results are obtained when measured using two analyzers MEDAS and ACCUNIQ (r=0.938, p<0.05 5); ANTRA and ACCUNIQ give a lower correlation (r=0.819, p<0.05), the lowest correlation is shown between the ANTRA method and MEDASS (r=0.715, p<0.05). When determining body fat mass, the methods give the least correlations than when determining lean body mass: the closest results are obtained when measured using two analyzers – MEDASS and ACCUNIQ (r=0.677; p<0.05)), ANTRA and ACCUNIQ give a lower correlation (r=0.598; p<0.05) (moreover, the correlation is not significant).Conclusion. Determination of the body composition of athletes is possible by any of the methods (caliperometry, bioimpedancemetry), given that the same method will be used for dynamic studies.

Publisher

Alfmed LLC

Subject

Materials Chemistry,Economics and Econometrics,Media Technology,Forestry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3