Mechanical Analysis of the Connection Structure of a Double-Layered Valve Stent within an Annuloplasty Ring

Author:

Dong Ke,He Zhaoming

Abstract

Background: In this study, to address the failure of mitral valve repair surgery, a novel valve-in-ring model for an artificial mitral valve annuloplasty ring and a new double-layer mitral valve were established. A suitable number and length of ventricular fixation struts within the annuloplasty ring, as well as the implantation depth, result in variations in stress and strain for the inner and outer stent layers. Methods: The compression and self-expansion model of the stent was established via finite element analysis. The changes in stress and strain were analyzed by setting the length and number of the ventricular fixed struts and implantation depth. Results: When only affected by factors such as blood pressure, the maximum stresses of stent structures with three and six ventricular fixed struts are 476 and 222 MPa, respectively, in the right posterior annular region. At implantation depths of 0, 0.5, 1, and 2 mm, the maximum stresses are located in the left posterior annular region of the outer stent and are 740, 697, 709, and 742 MPa, respectively, and the maximum displacements of the inner stent are all in the right posterior ventricular fixed strut region of the posterior annulus and are 3.71, 3.10, 2.48, and 1.87 mm, respectively. In the three and six ventricular fixed strut stents, when the ventricular fixed strut length is 3, 4, and 5 mm, the maximum stresses are 570, 557, and 621 MPa and 674, 666, 644 MPa, respectively. Conclusions: Appropriately increasing the number of ventricular fixed struts can effectively reduce damage to the stent inside the body, and the damage to the stent is relatively consistent across different implantation depths; however, the right side of the stent's posterior annulus is particularly susceptible to damage. However, if the implantation depth is lower, the impact on the inner stent will be more significant. As the number of ventricular fixed struts increases, the strut length variation has a relatively stable impact on stent damage.

Publisher

Forum Multimedia Publishing LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3