As a result of the analytical studies of the designs of thermionic reactor-converters, four groups of technical solutions have been identified that differ in the method of heat transfer from the fuel to the emitters of the thermionic converter: one option with direct in-core transfer (combining the fuel cladding with the emitter) and three options with thermionic converters taken away from the reactor core, in which case the heat is removed either by heat pipes (common or individual for each fuel element) or is arranged based on the principle of a steam chamber. The article describes the advantages and disadvantages for each of these methods. It is shown that at present the most developed design remains the version with in-core power conversion and, in the future it will be based on the steam chamber since the ingress of gaseous fission products into the inter-electrode gap as well as the influence of fuel swelling on the inter-electrode gap size are excluded and it ensures constant temperature and heat flux density on the surface of all emitters of the thermionic converters, which makes it possible to select the optimal operating parameters for them. A model of a thermionic reactor-converter with a steam chamber containing a reactor core and a zone of thermionic converters has been developed in which the fuel element of the reactor core and the power generating channels of the thermionic converter are separated in space, covered with a capillary porous structure and interconnected by a honeycomb capillary porous spacer plate to provide for circulation of the liquid metal coolant and to let its steam pass through. Neutronic calculations have demonstrated the possibility of a duration for the reactor campaign in excess of ten years following the nuclear safety regulations when a gadolinium oxide coating is applied to the surface of the fuel rods and the reactor vessel in the area of the reactor core. The assessment of thermal and electrical parameters shows that, due to the constant temperature and heat flux density on the surface of all emitters and optimization of the power conversion process for all the thermionic converters, one can expect to reach the maximum efficiency of 20%.

Publisher

Pensoft Publishers

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3