Clinical application of titanium nickelide knitwear based on the quantitative assessment of rheological similarity to soft biological tissues

Author:

Marchenko E. S.1ORCID,Yasenchuk Yu. F.1ORCID,Gunther S. V.1ORCID,Kozulin A. A.1ORCID,Vetrova A. V.1ORCID,Polonyankin A. S.2ORCID,Fatyushina O. A.2ORCID,Vusik A. N.2ORCID

Affiliation:

1. National Research Tomsk State University

2. Siberian State Medical University

Abstract

Samples of metal knitted mesh made of the 40 μm, 60 μm and 90 μm diameter TiNi wires are studied by uniaxial tension to rupture and uniaxial cyclic tension. It was found that the metal knitted TiNi mesh behaves like a hyperelastic material under uniaxial tension in contrast to the superelastic wire from which it is made. Using the rheological models of Gent, Neo-Hookean, Mooney–Rivlin and Bergstrom-Boyce, the calculation of the cyclic tension of the knitted mesh was carried out. The similarity of the mechanical behavior of knitted mesh and biological tissues is shown. Criteria for quantitative assessment of the biomechanical compatibility of a knitted mesh implant for plasty of hyperelastic biological tissues are proposed.The main criteria for the rheological similarity of knitted mesh and soft tissues are the ultimate tensile strength, elastic modulus and the range of low-modulus and high-modulus elastic strain under loading and unloading; the residual strain value during cyclic tension.It has been found that knitted mesh made of superelastic TiNi wire exhibits a rubber-like behavior characteristic of hyperelastic materials under soft zero cyclic tension. At the same time, in the most loaded contact areas of the superelastic TiNi wire, the martensitic transition did not affect the tension cycles is due to friction, which counteracts the recovery of elastic strain during unloading. It has been established that the Bergstrom–Boyce model is closest in terms of the stress–strain diagram to the knitted mesh and biological tissues. Knitted mesh implants made of nickeide titanium wire were used for plasty of soft tissues and musculoskeletal complexes. The developed method for quantitative assessment diagram of the hyperelastic knittes mesh. The residual strain during the first two tension of the biocompatibility of the implant and biological tissue make it possible to choosу knitteв mesh with a certain wire diametre, focusing on the forces developed by the knitted mesh and the variable elasticity modulus. The knitted mesh was applied without additional fixation, using elastic self-fixation of knitted mesh loops into soft tissues.

Publisher

Research Institute of Microsurgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Experimental and computational study of the NiTi thin wires mechanical behavior;Mechanics of Advanced Materials and Structures;2024-04-18

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3