Performance Evaluation of Honeywell Silicon Piezoresistive Pressure Transducers for Oceanographic and Limnological Measurements*

Author:

Kumar Vijay1,Joseph Antony1,Prabhudesai R. G.1,Prabhudesai S.1,Nagvekar Surekha1,Damodaran Vimala1

Affiliation:

1. National Institute of Oceanography, Dona Paula, Goa, India

Abstract

Abstract Simultaneous calibrations of three temperature-compensated piezoresistive ruggedized precision “absolute” pressure transducers (Honeywell model PPTR0040AP5VB-BD), which have been designed specially for long-term coastal oceanographic and limnological measurements, have been carried out at four differing temperatures (10°, 20°, 30°, and 40°C) to evaluate their suitability for such applications. The full-scale pressure range of these shallow water absolute pressure sensors is ≈ 2800 hPa (equivalent to water depth of ≈ 18 m). Measurement results have been used to examine the transducers’ performance indicators, such as zero-point offset, accuracy, linearity, hysteresis, temperature sensitivity, and slope. Differing piezoresistive ruggedized precision absolute pressure transducers (PPTRs) exhibited differing zero-point offset values, ranging from 2 to −79 hPa. Temperature sensitivity of zero-point offset was ≈0.3 hPa over the temperature range 10°–40°C. The mean hysteresis over the full-scale absolute pressure range (≈2800 hPa) varied from approximately 2 to 8 hPa over the temperature range 10°–40°C. The slope of the least squares–fitted linear graph (taking the mean of ascending and descending pressures) was close to the ideal value of unity (deviation from 1 over the temperature range 10°–40°C was in the range of −0.001 to +0.005). Linearity was excellent, its mean over the entire pressure range being between ≈ −0.006% and 0.008% of full-scale (FS) over the above temperature range. The worst performance was exhibited at input pressures below ≈1500 hPa. Zero-point offset has played a significant role in deteriorating the accuracy of the PPTR, the mean accuracy (within ≈0.1% and −5%) having been exhibited by those transducers having offsets of 2 and −79 hPa, respectively. The mean accuracy exhibited temperature sensitivity of ≈1% in the range 10°–20°C and negligible sensitivity beyond 20°C. Use of a calibration equation significantly improved the mean static accuracy obtainable from the PPTR, to between −0.04% and 0.01% of FS. Evaluation results have indicated that a suitably calibrated temperature-compensated Honeywell PPTR provides an alternate cost-effective means for pressure measurements for coastal oceanographic and limnological studies.

Publisher

American Meteorological Society

Subject

Atmospheric Science,Ocean Engineering

Reference8 articles.

1. Quartz transducers for precision under pressure.;Busse;Mech. Eng.,1987

2. Generalized performance characteristics of instruments.;Doebelin,1983

3. Evaluation of pressure transducers under turbid natural waters.;Joseph;J. Atmos. Oceanic Technol.,1999

4. Evaluation and performance enhancement of a pressure transducer under flows, waves, and a combination of flows and waves.;Joseph;J. Atmos. Oceanic Technol.,2000

5. Joseph, A., V.Kumar, S.Prabhudesai, P.Mehra, E.Desa, and S. M.Nagvekar, 2005: System for calibration of pressure transducers. U.S. Patent No. 6848292.

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3