Radioiodinated soluble canine fibrin. Preparation and evaluation as a thrombus localizing agent in the dog.

Author:

Coleman R E,Harwig S S,Harwig J F,Sherman L A,Welch M J

Abstract

To develop a thrombus localizing tracer which has characteristics superior to labeled fibrinogen for external detection, we evaluated radioiodinated soluble fibrin. Labeled soluble fibrin was prepared by clotting and dissolving radioiodinated (131I) canine fibrinogen under specified conditions. Biological clearance studies revealed rapid clearance of the labeled soluble fibrin from the blood with a half-life of 5 hours. The accumulation of labeled soluble fibrin and fibrinogen in induced venous thrombi, coronary artery thrombi, and the myocardium was compared in dogs. In venous thrombi, soluble fibrin and fibrinogen exhibited maximum thrombus-blood ratios when they were injected 4 hours after thrombus induction; the thrombus-blood ratio was greater for soluble fibrin than it was for fibrinogen when these agents were injected 4, 8, or 24 hours after thrombosis induction. In induced coronary artery thrombi, soluble fibrin and fibrinogen accumulated to the same extent. Since the blood clearance of soluble fibrin is faster than that of fibrinogen, a higher thrombus-blood ratio was obtained with soluble fibrin in coronary artery thrombi. The thrombus-infarcted myocardium, thrombus-normal myocardium, and infarcted myocardium-normal myocardium ratios obtained with soluble fibrin were slightly higher than those obtained with fibrinogen. Thus, soluble fibrin offers some advantages when it is compared with fibrinogen as a thrombus detecting agent.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Reference39 articles.

1. Current status of the radioactive labeled fibrinogen method in the detection of venous thrombosis. In Pulmonary Thromboembolism, edited by KM Moser and M Stein. Chicago, Yearbook Medical Publishers;Inc.,1973

2. The 125I Fibrinogen Uptake Test

3. The Diagnosis of Deep Vein Thrombosis Using the 125I Fibrinogen Test

4. Scintigraphic detection of deep vein thrombosis with131I-fibrinogen;J Nucl Med,1974

5. 123I-fibrinogen imaging of thrombi in dogs (abstr);J Nucl Med,1974

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Rationale for the use of conjunctive anticoagulation during thrombolysis;Coronary Artery Disease;1996-07

2. Applications of Radioiodinated Macromolecules;Radioiodination: Theory, Practice, and Biomedical Applications;1992

3. Radiopharmaceuticals for thrombus detection;Seminars in Nuclear Medicine;1990-01

4. 111In-Labeled Platelets for the Detection of Vascular Disorders in Animal Models;Animal Models in Radiotracer Design;1983

5. Labeled proteins, their preparation and applications;Topics in Current Chemistry;1983