Validity of the Xenon 133 Method for Measurement of Muscle Blood Flow Evaluated by Simultaneous Venous Occlusion Plethysmography

Author:

LASSEN NIELS A.1,LINDBJERG IB F.1,DAHN INGE1

Affiliation:

1. Department of Clinical Physiology, Bispebjerg Hospital Copenhagen, Denmark Department of Clinical Physiology, Lasarettet, Lund, Sweden

Abstract

Calf blood flow has been measured simultaneosuly by the Xe 133 clearance method in m. tibialis anterior and m. gastrocnemius and by venous occlusion plethysmography in normal man and in patients with intermittent claudication. At rest Xe 133 muscle blood flow ( MBF xe ) averaged 1.6 ml/100 g/min while plethysmographic total calf blood flow (calf BF) was higher in each instance and averaged 3.0 ml/100 g/min. There was no difference between normal legs and legs with occlusive vascular disease in this respect. Following one to five minutes of arterial occlusion, reactive hyperemia was seen with both methods, the rapid changes being most readily observed with the plethysmographic method. After exhaustive muscular exercise during ischemia in normal man maximal MBF xe averaged 40 ml/100 g/min (48 ml/100 g/min over m. tibialis anterior and 32 ml/100 g/min over m. gastrocnemius). The maximal calf BF averaged 42 ml/100 g/min. The rate of return of blood flow to the resting level was also quite similar with both methods. In the patients with claudication both methods showed a subnormal and delayed hyperemic reaction following ischemic work, but the MBF xe was consistently lower. The results obtained indicate that the Xe 133 modification of Kety's local clearance method for measurement of muscular blood flow in man is essentially valid.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Reference7 articles.

1. Measurement of regional circulation by the local clearance of radioactive sodium

2. Muscle Blood Flow in Normal Man and in Patients with Intermittent Claudication Evaluated by Simultaneous Xe133 and Na24 Clearances *

3. LASSEN N. A. H0EDT-RASMUSSEN K. LJNDBJEHC I. F. AND MUNOC O.: Blood flow of skeletal muscle determined by the use of inert highly diffusible radioactive indicators. Ninth meeting of Scandinavian Society for Clinical Chemistry and Clinical Physiology Sandefjord Norway June 1963. Scand. J. Clin. Lab. Invest. 15: suppl. 76: 61 1963.

4. MEASUREMENT OF BLOOD-FLOW THROUGH SKELETAL MUSCLE BY INTRAMUSCULAR INJECTION OF XENON-133

5. Equilibrium distribution of radioxenon in tissue: xenon-hemoglobin association curve

Cited by 89 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Clinical imaging techniques for assessing vascular risk and complications in the lower extremities;Diabetes and Cardiovascular Disease;2021

2. Radionuclide Imaging;Imaging in Peripheral Arterial Disease;2019-09-14

3. Resting Blood Flow in the Skin: Does it Exist, and What is the Influence of Temperature, Aging, and Diabetes?;Journal of Diabetes Science and Technology;2012-05

4. A COMPREHENSIVE TISSUE PROPERTIES DATABASE PROVIDED FOR THE THERMAL ASSESSMENT OF A HUMAN AT REST;Biophysical Reviews and Letters;2010-09

5. Arterial Physiology;Rutherford's Vascular Surgery;2010