Circuit Determinants of Ventricular Tachycardia Cycle Length

Author:

Nishimura Takuro1ORCID,Upadhyay Gaurav A.1,Aziz Zaid A.1,Beaser Andrew D.1ORCID,Shatz Dalise Y.1ORCID,Nayak Hemal M.1,Tung Roderick1ORCID

Affiliation:

1. The University of Chicago Medicine, Center for Arrhythmia Care, Pritzker School of Medicine, Department of Medicine, Section of Cardiology, IL.

Abstract

Background: Fast ventricular tachycardias (VTs) have historically been attributed to shorter path lengths with smaller reentrant circuit dimensions in animal models. The relationship between the dimensions of the reentrant VT circuit and tachycardia cycle length (TCL) has not been examined in humans. This study aimed to analyze the determinants of the rate of human VT with comparison of circuit dimensions and conduction velocity (CV) across a wide range of both stable and unstable VTs delineated by high-resolution mapping. Methods: Fifty-four VTs with complete circuit delineation (>90% TCL) by high-resolution multielectrode mapping were analyzed in 49 patients (men, 88%; age, 65 years [58–71 years]; nonischemic, 47%). Fast VT was defined as TCL <333 milliseconds (rate >180 bpm). Unstable VT was defined by hemodynamic deterioration with an intrinsic mean arterial pressure <60 mm Hg during a sustained episode. Results: The median TCL of VT was 365 milliseconds (306–443 milliseconds), and 24 fast VTs were characterized. A wide range of CVs was observed within the entrance (0.03–0.55 m/s), common pathway (0.03–0.77 m/s), exit (0.03–0.53 m/s), and outer loop (0.17–1.13 m/s). There were no significant differences in the median dimensions of the isthmus and path length between fast and slow VTs and between unstable and stable VTs. The outer loop CV was the only circuit component that correlated with TCL in both ischemic cardiomyopathy ( r =−0.5, P =0.006) and nonischemic cardiomyopathy ( r =−0.45, P =0.028). The duration of the longest diastolic electrogram was inversely correlated with the dimensions of common pathway (length: r =−0.46, P =0.001, width: r =−0.3, P =0.047) and predictive of rapid VT termination by a single radiofrequency application ( r =−0.41, P =0.023). Conclusions: Because of a wide spectrum of CV observed within the reentrant path during human VT, the dimensions of the circuit were not predictive of VT cycle length. For the first time, we demonstrate that the CV of the outer loop, rather than isthmus, is the principal determinant of the rate of VT. The size of the circuit was similar between fast and slow VTs and between unstable and stable VTs. Long, continuous electrograms were indicative of spatially confined isthmus dimensions, confirmed by rapid termination of VT during radiofrequency delivery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 33 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3