Saphenous Vein Grafts With Multiple Versus Single Distal Targets in Patients Undergoing Coronary Artery Bypass Surgery

Author:

Mehta Rajendra H.1,Ferguson T. Bruce1,Lopes Renato D.1,Hafley Gail E.1,Mack Michael J.1,Kouchoukos Nicholas T.1,Gibson C. Michael1,Harrington Robert A.1,Califf Robert M.1,Peterson Eric D.1,Alexander John H.1

Affiliation:

1. From the Duke Clinical Research Institute, Duke University Medical Center, Durham, NC (R.H.M., R.D.L., G.E.H., R.A.H., R.M.C., E.D.P., J.H.A.); The Brody School of Medicine, East Carolina University, Greensville, NC (B.F.); Medical City Hospital, Dallas, TX (M.J.M.); Missouri Baptist Medical Center, St. Louis, MO (N.T.K); and Beth Israel Deaconess Medical Center, Boston, MA (C.M.G.).

Abstract

Background— Limited information exists on the intermediate-term graft patency and 5-year clinical outcomes of patients receiving saphenous vein grafts with multiple (m-SVG) versus single distal targets (s-SVG) during coronary artery bypass graft (CABG) surgery in the current era. Methods and Results— We studied the association of the use of m-SVG versus s-SVG conduits with 1-year SVG failure (defined as ≥75% angiographic stenosis) and 5-year clinical events (death; death or myocardial infarction [MI]; and death, MI, or revascularization) in 3014 patients undergoing their first CABG surgery enrolled in the Project of Ex-vivo Vein Graft Engineering via Transfection (PREVENT) IV. Of 3014 patients enrolled in PREVENT IV, 1045 (34.7%) had ≥1 m-SVGs during CABG. Vein graft failure at 1-year was higher for m-SVG compared with s-SVG (adjusted odds ratio 1.24, 95% confidence interval 1.03 to 1.48). At 5 years, the adjusted composite of death, MI (including perioperative MI), or revascularization (hazard ratio 1.15, 95% confidence interval 1.00 to 1.31) and death or MI (hazard ratio 1.21, 95% confidence interval 1.03 to 1.43) were significantly higher in patients receiving m-SVGs. Conclusions— In patients undergoing first CABG surgery, the use of m-SVG was associated with a higher 1-year vein graft failure rate and trends toward worse clinical outcomes. Additional studies are needed to better understand the most appropriate conduit to improve long-term graft patency and clinical outcomes of patients undergoing CABG surgery. In the meantime, these data should encourage the use of s-SVG over m-SVG when feasible.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3