Long-Term Safety and Effectiveness of Mechanical Versus Biologic Aortic Valve Prostheses in Older Patients

Author:

Brennan J. Matthew1,Edwards Fred H.1,Zhao Yue1,O’Brien Sean1,Booth Michael E.1,Dokholyan Rachel S.1,Douglas Pamela S.1,Peterson Eric D.1

Affiliation:

1. From Duke Clinical Research Institute, Durham, NC (J.M.B., Y.Z., S.O., M.E.B., R.S.D., P.S.D., E.D.P.); and the Division of Cardiothoracic Surgery, University of Florida Health Science Center, Jacksonville, FL (F.H.E.).

Abstract

Background— There is a paucity of long-term data comparing biological versus mechanical aortic valve prostheses in older individuals. Methods and Results— We performed follow-up of patients aged 65 to 80 years undergoing aortic valve replacement with a biological (n=24 410) or mechanical (n=14 789) prosthesis from 1991 to 1999 at 605 centers within the Society of Thoracic Surgeons Adult Cardiac Surgery Database using Medicare inpatient claims (mean, 12.6 years; maximum, 17 years; minimum, 8 years), and outcomes were compared by propensity methods. Among Medicare-linked patients undergoing aortic valve replacement (mean age, 73 years), both reoperation (4.0%) and endocarditis (1.9%) were uncommon to 12 years; however, the risk for other adverse outcomes was high, including death (66.5%), stroke (14.1%), and bleeding (17.9%). Compared with those receiving a mechanical valve, patients given a bioprosthesis had a similar adjusted risk for death (hazard ratio, 1.04; 95% confidence interval, 1.01–1.07), higher risks for reoperation (hazard ratio, 2.55; 95% confidence interval, 2.14–3.03) and endocarditis (hazard ratio, 1.60; 95% confidence interval, 1.31–1.94), and lower risks for stroke (hazard ratio, 0.87; 95% confidence interval, 0.82–0.93) and bleeding (hazard ratio, 0.66; 95% confidence interval, 0.62–0.70). Although these results were generally consistent among patient subgroups, bioprosthesis patients aged 65 to 69 years had a substantially elevated 12-year absolute risk of reoperation (10.5%). Conclusions— Among patients undergoing aortic valve replacement, long-term mortality rates were similar for those who received bioprosthetic versus mechanical valves. Bioprostheses were associated with a higher long-term risk of reoperation and endocarditis but a lower risk of stroke and hemorrhage. These risks varied as a function of a patient’s age and comorbidities.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 204 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3