Transapical Beating-Heart Mitral Valve Repair With an Expanded Polytetrafluoroethylene Cordal Implantation Device

Author:

Gammie James S.1,Wilson Peter1,Bartus Krzysztof1,Gackowski Andrzej1,Hung Judy1,D’Ambra Michael N.1,Kolsut Piotr1,Bittle Gregory J.1,Szymanski Piotr1,Sadowski Jerzy1,Kapelak Boguslaw1,Bilewska Agata1,Kusmierczyk Mariusz1,Ghoreishi Mehrdad1

Affiliation:

1. From the Division of Cardiac Surgery, University of Maryland School of Medicine, Baltimore (J.S.G., G.J.B., M.G.); Jagiellonian University, Medical College, John Paul II Hospital, Krakow, Poland (K.B., A.G., J.S., B.K.); Institute of Cardiology, Warsaw, Poland (P.K., P.S., A.B., M.K.); Division of Cardiac Anesthesiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA (M.N.D.); Division of Cardiology, Massachusetts General Hospital, Harvard Medical School, Boston (J.H.); and Harpoon...

Abstract

Background: Degenerative mitral valve (MV) disease is a common cause of severe mitral regurgitation (MR) and accounts for the majority of MV operations. Conventional MV surgery requires cardiopulmonary bypass, aortic cross-clamping, cardioplegia, and a thoracotomy or sternotomy and, therefore, is associated with significant disability, risks, and unpredictable rates of MV repair. Transesophageal echocardiography–guided beating-heart MV repair with expanded polytetrafluoroethylene cordal insertion has the potential to significantly reduce surgical morbidity. We report the first-in-human clinical experience with a novel preformed expanded polytetrafluoroethylene knot implantation device (Harpoon TSD-5) designed to treat degenerative MR. Methods: Through a small left thoracotomy, the device was inserted into the heart and guided by transesophageal echocardiography to the ventricular surface of the prolapsed leaflet. Multiple expanded polytetrafluoroethylene cords were anchored in the leaflet and then adjusted to the correct length to restore MV leaflet coaptation and secured at the epicardium. Results: Eleven patients with posterior leaflet prolapse and severe MR, with mean±SD age of 65±13 years and mean ejection fraction of 69±7%, were treated with 100% procedural success. Immediate postprocedural mean MR grade was trace. At 1 month, the mean MR grade was mild with significant decreases in end-diastolic volume (139 to 107 mL; P =0.03) and left atrial volume (118 to 85 mL; P =0.04). Conclusions: A novel device used for beating-heart image-guided MV repair demonstrates a significant reduction in MR with favorable left ventricular and left atrial reverse remodeling. This approach has the potential to decrease invasiveness and surgical morbidity. Further follow-up is necessary to assess long-term efficacy. Clinical Trial Registration: URL: https://clinicaltrials.gov . Unique identifier: NCT02432196.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3