Improvement in Coronary Blood Flow Velocity With Acute Biventricular Pacing Is Predominantly Due to an Increase in a Diastolic Backward-Travelling Decompression (Suction) Wave

Author:

Kyriacou Andreas1,Whinnett Zachary I.1,Sen Sayan1,Pabari Punam A.1,Wright Ian1,Cornelussen Richard1,Lefroy David1,Davies D. Wyn1,Peters Nicholas S.1,Kanagaratnam Prapa1,Mayet Jamil1,Hughes Alun D.1,Francis Darrel P.1,Davies Justin E.1

Affiliation:

1. From the International Center for Circulatory Health, National Heart and Lung Institute, Imperial College London, London, United Kingdom (A.K., Z.I.W., S.S., P.A.P., I.W., D.L., D.W.D., N.S.P., P.KI., J.M., A.D.H., D.P.F., J.E.D.); and Research & Technology, Bakken Research Center, Medtronic Inc., and Department of Physiology, CARIM, Maastricht University, Maastricht, The Netherlands (R.C.).

Abstract

Background— Normal coronary blood flow is principally determined by a backward-traveling decompression (suction) wave in diastole. Dyssynchronous chronic heart failure may attenuate suction, because regional relaxation and contraction overlap in timing. We hypothesized that biventricular pacing, by restoring left ventricular (LV) synchronization and improving LV relaxation, might increase this suction wave, improving coronary flow. Method and Results— Ten patients with chronic heart failure (9 males; age 65±12; ejection fraction 26±7%) with left bundle-branch block (LBBB; QRS duration 174±18 ms) were atriobiventricularly paced at 100 bpm. LV pressure was measured and wave intensity calculated from invasive coronary flow velocity and pressure, with native conduction (LBBB) and during biventricular pacing at atrioventricular (AV) delays of 40 ms, 120 ms, and separately preidentified hemodynamically optimal AV delay. In comparison with LBBB, biventricular pacing at separately preidentified hemodynamically optimal AV delay (BiV-Opt) enhanced coronary flow velocity time integral by 15% (7%–25%) ( P =0.007), LV dP/dt max by 15% (10%–21%) ( P =0.005), and neg dP/dt max by 17% (9%–22%) ( P =0.005). The cumulative intensity of the diastolic backward decompression (suction) wave increased by 26% (18%–54%) ( P =0.005). The majority of the increase in coronary flow velocity time integral occurred in diastole (69% [41%–84% ]; P =0.047). The systolic compression waves also increased: forward by 36% (6%–49%) ( P =0.022) and backward by 38% (20%–55%) ( P =0.022). Biventricular pacing at AV delays of 120 ms generated a smaller LV dP/dt max (by 12% [5%–23% ], P =0.013) and neg dP/dt max (by 15% [8%–40% ]; P =0.009) increase than BiV-Opt, against LBBB as reference; BiV-Opt and biventricular pacing at AV delays of 120 ms were not significantly different in coronary flow velocity time integral or waves. Biventricular pacing at AV delays of 40 ms was no different from LBBB. Conclusions— When biventricular pacing improves LV contraction and relaxation, it increases coronary blood flow velocity, predominantly by increasing the dominant diastolic backward decompression (suction) wave.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 34 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3