The Swan-Ganz Catheters: Past, Present, and Future

Author:

Chatterjee Kanu1

Affiliation:

1. From the Chatterjee Center for Cardiac Research, University of California, San Francisco.

Abstract

The Swan-Ganz balloon flotation catheter was introduced in 1970. It can be placed at the bedside within a few minutes even in critically ill patients. Although placement of these catheters is not difficult, some training and experience are required to avoid complications and for proper interpretation of the hemodynamic data that can be obtained by pulmonary artery catheterization. Because of the many advantages of balloon flotation catheters compared with conventional catheters, they have been used without a proper indication and frequently overused in critical care units, resulting in many complications, including mortality. The prospective randomized trials have reported that in the majority of clinical circumstances, the routine use of balloon flotation catheters is not indicated. These results are not surprising because balloon flotation catheters are diagnostic and not therapeutic tools. That we have learned a great deal about hemodynamics in critically ill patients with the use of balloon flotation catheters should not be ignored or forgotten. Furthermore, our clinical knowledge of hemodynamics has been made possible because of extensive experience gained from directly determined hemodynamics with the use of balloon flotation catheters. It should also be realized that despite the introduction and refinement of newer noninvasive imaging modalities, a number of clinical circumstances exist in which determination of hemodynamics with the use of a balloon flotation catheter is necessary and should be considered, but only by experienced physicians. With the proper use of Swan-Ganz catheters, our knowledge of hemodynamics has been enhanced considerably. Its abuse, particularly by relatively inexperienced operators, has resulted in serious complications, including death. Prospective randomized clinical trials have demonstrated that the routine use of Swan-Ganz catheters does not provide any benefit. However, use of the Swan-Ganz catheter is still indicated in many situations.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference42 articles.

1. Die Sondierung des Rechten Herzens

2. Cournand AF. Nobel lecture December 11 1956. In: Nobel Lectures Physiology and Medicine 1942–1962. Amsterdam The Netherlands: Elsevier Publishing Co; 1964: 529.

3. DIAGNOSTIC RIGHT-HEART CATHETERISATION WITH MINIATURE CATHETERS IN SEVERELY ILL PATIENTS

4. Construction and use of self-guiding, right heart and pulmonary artery catheter

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3