Syncope in High-Risk Cardiomyopathy Patients With Implantable Defibrillators: Frequency, Risk Factors, Mechanisms, and Association With Mortality

Author:

Ruwald Martin H.1,Okumura Ken1,Kimura Takeshi1,Aonuma Kazutaka1,Shoda Morio1,Kutyifa Valentina1,Ruwald Anne-Christine H.1,McNitt Scott1,Zareba Wojciech1,Moss Arthur J.1

Affiliation:

1. From the Heart Research Follow-up Program, University of Rochester Medical Center, Rochester, NY (M.H.R., V.K., A.-C.H.R., S.M., W.Z., A.J.M.); Department of Cardiology, Gentofte Hospital, Hellerup, Denmark (M.H.R., A.-C.H.R.); Department of Cardiology, Hirosaki University Hospital, Hirosaki, Japan (K.O.); Department of Cardiology, Kyoto University Hospital, Kyoto, Japan (T.K.); Department of Cardiology, Tsukuba University Hospital, Tsukuba, Japan (K.A.); and Department of Cardiology, Tokyo Women’s...

Abstract

Background— There is a relative paucity of studies investigating the mechanisms of syncope among heart failure patients with implantable cardioverter-defibrillators, and it is controversial whether nonarrhythmogenic syncope is associated with increased mortality. Methods and Results— The Multicenter Automatic Defibrillator Implantation Trial–Reduce Inappropriate Therapy (MADIT-RIT) randomized 1500 patients to 3 different implantable cardioverter-defibrillator programming arms: (1) Conventional programming with therapy for ventricular tachycardia ≥170 bpm; (2) high-rate cutoff with therapy for ventricular tachycardia ≥200 bpm and a monitoring zone at 170 to 199 bpm, and (3) prolonged 60-second delay with a monitoring zone before therapy. Syncope was a prespecified safety end point that was adjudicated independently. Multivariable Cox models were used to identify risk factors associated with syncope and to analyze subsequent risk of mortality. During follow-up, 64 of 1500 patients (4.3%) had syncope. The incidence of syncope was similar across the 3 treatment arms. Prognostic factors for all-cause syncope included the presence of ischemic cardiomyopathy (hazard ratio [HR], 2.48; 95% confidence interval [CI], 1.42–4.34; P =0.002), previous ventricular arrhythmias (HR, 2.99; 95% CI, 1.18–7.59; P =0.021), left ventricular ejection fraction ≤25% (HR, 1.65; 95% CI, 0.98–2.77; P =0.059), and younger age (by 10 years; HR, 1.25; 95% CI, 1.00–1.52; P =0.046). Syncope was associated with increased risk of death regardless of its cause (arrhythmogenic syncope: HR, 4.51; 95% CI, 1.39–14.64, P =0.012; nonarrhythmogenic syncope: HR, 2.97; 95% CI, 1.07–8.28, P =0.038). Conclusions— Innovative programming of implantable cardioverter-defibrillators with therapy for ventricular tachycardia ≥200 bpm or a long delay is not associated with increased risk of arrhythmogenic or all-cause syncope, and syncope caused by slow ventricular tachycardias (<200 bpm) is a rare event. The clinical risk factors associated with syncope are related to increased cardiovascular risk profile, and syncope is associated with increased mortality irrespective of the cause. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00947310.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 44 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3