Ventricular Fibrillation Conversion Testing After Implantation of a Subcutaneous Implantable Cardioverter Defibrillator

Author:

Friedman Daniel J.12,Parzynski Craig S.3,Heist E. Kevin4,Russo Andrea M.5,Akar Joseph G.3,Freeman James V.3,Curtis Jeptha P.3,Al-Khatib Sana M.12

Affiliation:

1. Division of Cardiology, Duke University Hospital, Durham, NC (D.J.F., S.M.A.-K.).

2. Duke Clinical Research Institute, Durham, NC (D.J.F., S.M.A.-K.).

3. Yale University School of Medicine, New Haven, CT (C.S.P., J.G.A., J.V.F., J.P.C.).

4. Cardiac Arrhythmia Service, Massachusetts General Hospital, Boston (E.K.H.).

5. Cooper Medical School of Rowan University, Camden, NJ (A.M.R.).

Abstract

Background: Compared with transvenous implantable cardioverter defibrillators (ICDs), subcutaneous (S)-ICDs require a higher energy for effective defibrillation. Although ventricular fibrillation conversion testing (CT) is recommended after S-ICD implantation to ensure an adequate margin between the defibrillation threshold and maximum device output (80J), prior work found that adherence to this recommendation is declining. Methods: We studied first-time recipients of S-ICDs (between September 28, 2012, and April 1, 2016) in the National Cardiovascular Database Registry ICD Registry to determine predictors of use of CT, predictors of an insufficient safety margin (ISM, defined as ventricular fibrillation conversion energy >65J) during testing, and inhospital outcomes associated with use of CT. Multivariable logistic regression analysis was used to predict use of CT and ISM. Inverse probability weighted logistic regression analysis was used to examine the association between use of CT and inhospital adverse events including death. Results: CT testing was performed in 70.7% (n=5624) of 7960 patients with S-ICDs. Although deferral of CT was associated with several patient characteristics (including increased body mass index, increased body surface area, severely reduced ejection fraction, dialysis dependence, warfarin use, anemia, and hypertrophic cardiomyopathy), the facility effect was comparatively more important (area under the curve for patient level versus generalized linear mixed model: 0.619 versus 0.877). An ISM occurred in 6.9% (n=336) of 4864 patients without a prior ICD and was more common among white patients and those with ventricular pacing on the preimplant ECG, higher preimplant blood pressure, larger body surface area, higher body mass index, and lower ejection fraction. A risk score was able to identify patients at low (<5%), medium (5% to 10%), and high risk (>10%) for ISM. CT testing was not associated with a composite of inhospital complications including death. Conclusions: Use of CT testing after S-ICD implantation was driven by facility preference to a greater extent than patient factors and was not associated with a composite of inhospital complications or death. ISM was relatively uncommon and is associated with several widely available patient characteristics. These data may inform ICD system selection and a targeted approach to CT.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3