Randomized Trial of Cutting Balloon Compared With High-Pressure Angioplasty for the Treatment of Resistant Pulmonary Artery Stenosis

Author:

Bergersen Lisa1,Gauvreau Kimberlee1,Justino Henri1,Nugent Alan1,Rome Jonathon1,Kreutzer Jacqueline1,Rhodes John1,Nykanen David1,Zahn Evan1,Latson Larry1,Moore Phillip1,Lock James1,Jenkins Kathy1

Affiliation:

1. From the Children's Hospital Boston, Boston, MA (L.B., K.G., J.L., K.J.); Texas Children's Hospital, Houston (H.J.); UT Southwestern Medical Center, Dallas, TX (A.N.); Children's Hospital of Philadelphia, Philadelphia, PA (J. Rome); Children's Hospital Pittsburgh, Pittsburgh, PA (J.K.); Duke University Medical Center, Durham, NC (J. Rhodes); Miami Children's Hospital, Miami, FL (D.N., E.Z.); Cleveland Clinic Foundation, Cleveland, OH (L.L.); and University of California San Francisco, San Francisco ...

Abstract

Background— We sought to determine the safety and efficacy of Cutting Balloon therapy (CB) compared with conventional high-pressure balloon therapy (HPB) for the treatment of pulmonary artery stenosis. Methods and Results— This prospective, randomized, multicenter, investigational device exemption trial compared CB with HPB. Patient eligibility was determined at the precatheterization assessment; vessel eligibility was determined at catheterization. In all vessels, low-pressure balloon dilation to 8 atm was performed, and if it was not successful, the vessel was randomized to CB or HPB. The primary efficacy outcome was percent change in minimum lumen diameter. A core laboratory performed all vessel measurements and angiographic assessment of vessel damage. The primary safety outcome was any serious adverse event attributable to vessel dilation as assessed by the Data and Safety Monitoring Board. Seventy-three patients from 8 institutions were enrolled between 2004 and 2008. In these patients, 72 vessels responded to low-pressure balloon dilation. Of the 173 vessels that met eligibility criteria, 107 were randomized to CB and 66 to HPB. In randomized vessels, CB therapy was associated with greater percent increase in lumen diameter (85% versus 52%; P =0.004). After crossover was introduced, 26 of 47 vessels treated with HPB underwent CB therapy and experienced an additional 48% increase in lumen diameter; the final diameter after CB was 99% greater than the initial diameter. There were no serious adverse events related to treatment in a study vessel. Conclusion— CB therapy for pulmonary artery stenosis not responsive to low-pressure balloon is more effective than HPB therapy and has an equivalent safety profile.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 48 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3