Personalized Rate-Response Programming Improves Exercise Tolerance After 6 Months in People With Cardiac Implantable Electronic Devices and Heart Failure

Author:

Gierula John1,Lowry Judith E.1,Paton Maria F.1,Cole Charlotte A.1,Byrom Rowenna1,Koshy Aaron O.1,Chumun Hemant1,Kearney Lorraine C.1,Straw Sam1,Bowen T. Scott2,Cubbon Richard M.1,Keenan Anne-Maree3,Stocken Deborah D.4,Kearney Mark T.1,Witte Klaus K.1

Affiliation:

1. Leeds Institute of Cardiovascular and Metabolic Medicine (J.G., J.E.L., M.F.P., C.A.C., R.B., A.O.K., H.C., L.C.K., S.S., R.M.C., M.T.K., K.K.W.), University of Leeds, United Kingdom.

2. Faculty of Biological Sciences, School of Medicine (T.S.B.), University of Leeds, United Kingdom.

3. School of Healthcare (A.M.K.), University of Leeds, United Kingdom.

4. Leeds Institute of Clinical Trials Research (D.D.S), University of Leeds, United Kingdom.

Abstract

Background: Heart failure with reduced ejection fraction (HFrEF) is characterized by blunting of the positive relationship between heart rate and left ventricular (LV) contractility known as the force-frequency relationship (FFR). We have previously described that tailoring the rate-response programming of cardiac implantable electronic devices in patients with HFrEF on the basis of individual noninvasive FFR data acutely improves exercise capacity. We aimed to examine whether using FFR data to tailor heart rate response in patients with HFrEF with cardiac implantable electronic devices favorably influences exercise capacity and LV function 6 months later. Methods: We conducted a single-center, double-blind, randomized, parallel-group trial in patients with stable symptomatic HFrEF taking optimal guideline-directed medical therapy and with a cardiac implantable electronic device (cardiac resynchronization therapy or implantable cardioverter-defibrillator). Participants were randomized on a 1:1 basis between tailored rate-response programming on the basis of individual FFR data and conventional age-guided rate-response programming. The primary outcome measure was change in walk time on a treadmill walk test. Secondary outcomes included changes in LV systolic function, peak oxygen consumption, and quality of life. Results: We randomized 83 patients with a mean±SD age 74.6±8.7 years and LV ejection fraction 35.2±10.5. Mean change in exercise time at 6 months was 75.4 (95% CI, 23.4 to 127.5) seconds for FFR-guided rate-adaptive pacing and 3.1 (95% CI, −44.1 to 50.3) seconds for conventional settings (analysis of covariance; P =0.044 between groups) despite lower peak mean±SD heart rates (98.6±19.4 versus 112.0±20.3 beats per minute). FFR-guided heart rate settings had no adverse effect on LV structure or function, whereas conventional settings were associated with a reduction in LV ejection fraction. Conclusions: In this phase II study, FFR-guided rate-response programming determined using a reproducible, noninvasive method appears to improve exercise time and limit changes to LV function in people with HFrEF and cardiac implantable electronic devices. Work is ongoing to confirm our findings in a multicenter setting and on longer-term clinical outcomes. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02964650.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3