Internal Versus External Electrical Cardioversion of Atrial Arrhythmia in Patients With Implantable Cardioverter-Defibrillator

Author:

Lüker Jakob1,Kuhr Kathrin2,Sultan Arian1,Nölker Georg3,Omran Hazem3,Willems Stephan4,Andrié René5,Schrickel Jan W.5,Winter Stefan6,Vollmann Dirk7,Tilz Roland R.8,Jobs Alexander89,Heeger Christian-H.8,Metzner Andreas10,Meyer Sven11,Mischke Karl12,Napp Andreas13,Fahrig Andreas14,Steinhauser Susanne2,Brachmann Johannes15,Baldus Stephan16,Mahajan Rajiv17,Sanders Prashanthan17,Steven Daniel1

Affiliation:

1. University of Cologne, University Hospital Cologne, Department of Electrophysiology (J.L., A.S., D.S.), Germany

2. Institute of Medical Statistics and Computational Biology (IMSB) (K.K., S.S.), Germany

3. Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Clinic for Electrophysiology, Bad Oeynhausen, Germany (G.N., H.O.).

4. Department of Electrophysiology, University Heart Center, Hamburg, Germany (S.W.).

5. Department of Internal Medicine II, University Hospital Bonn, Germany (R.A., J.W.S.).

6. St. Vinzenz Hospital, Cologne, Germany (S.W.).

7. Herz- & Gefäßzentrum Göttingen, Germany (D.V.).

8. Department of Cardiology, University Hospital Lübeck, Germany (R.R.T., A.J., C.H.H.).

9. Department of Internal Medicine/Cardiology, Heart Center Leipzig at University of Leipzig, Germany (A.J.).

10. Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany (A.M.).

11. Department of Cardiology, Heart Center Oldenburg, European Medical School Oldenburg-Groningen, Germany (S.M.).

12. Medical Clinic I, Leopoldina Hospital, Schweinfurt, Germany (K.M.).

13. Department of Internal Medicine I, RWTH Aachen University Hospital, Germany (A.N.).

14. Klinikum Leverkusen, Germany (A.F.).

15. Medical Clinic II, Coburg Hospital, Germany (J.B.).

16. Department of Cardiology (S.B.), Germany.

17. Center for Heart Rhythm Disorders, South Australian Health and Medical Research Institute (SAHMRI), University of Adelaide, Australia (R.M., P.S.).

Abstract

Background: Atrial arrhythmias are common in patients with implantable cardioverter-defibrillator (ICD). External shocks and internal cardioversion through commanded ICD shock for electrical cardioversion are used for rhythm-control. However, there is a paucity of data on efficacy of external versus internal cardioversion and on the risk of lead and device malfunction. We hypothesized that external cardioversion is noninferior to internal cardioversion for safety, and superior for successful restoration of sinus rhythm. Methods: Consecutive patients with ICD undergoing elective cardioversion for atrial arrhythmias at 13 centers were randomized in 1:1 fashion to either internal or external cardioversion. The primary safety end point was a composite of surrogate events of lead or device malfunction. Conversion of atrial arrhythmia to sinus rhythm was the primary efficacy end point. Myocardial damage was studied by measuring troponin release in both groups. Results: N=230 patients were randomized. Shock efficacy was 93% in the external cardioversion group and 65% in the internal cardioversion group ( P <0.001). Clinically relevant adverse events caused by external or internal cardioversion were not observed. Three cases of pre-existing silent lead malfunction were unmasked by internal shock, resulting in lead failure. Troponin release did not differ between groups. Conclusions: This is the first randomized trial on external vs internal cardioversion in patients with ICDs. External cardioversion was superior for the restoration of sinus rhythm. The unmasking of silent lead malfunction in the internal cardioversion group suggests that an internal shock attempt may be reasonable in selected ICD patients presenting for electrical cardioversion. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT03247738.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3