Multislice Computed Tomography Accurately Quantifies Left Atrial Size and Function After the MAZE Procedure

Author:

Yamanaka Kazuo1,Fujita Masatoshi1,Doi Kazuhiko1,Tsuneyoshi Hiroshi1,Yamazato Ario1,Ueno Katsuya1,Zen Eiwa1,Komeda Masashi1

Affiliation:

1. From the Divisions of Cardiovascular Surgery (K.Y., K.D., H.T., A.Y.), Radiology (K.U.), and Cardiology (E.Z.) Takeda Hospital; the School of Health Sciences (M.F.), Faculty of Medicine, Kyoto University; and the Department of Cardiovascular Surgery (M.K.), Graduate School of Medicine, Kyoto University, Kyoto, Japan.

Abstract

Background— Although the MAZE procedure allows for the recovery of sinus rhythm and left atrial (LA) mechanical function in the great majority of patients with chronic atrial fibrillation (AF), the effects of MAZE on the precise LA geometry and wall motion remain to be elucidated. We hypothesized that LA size and mechanical function in patients with chronic AF and mitral valvular disease are well restored after MAZE. Methods and Results— We studied 14 patients (MAZE group: mean±SD age, 63.9±8.6 years; 8 men and 6 women) who underwent MAZE for chronic AF and mitral valve surgery and 10 patients with sinus rhythm (coronary artery bypass graft [CABG] group: age, 70.0±7.9 years; 5 men and 5 women) who underwent CABG at Takeda Hospital between February 2002 and September 2005. MAZE was conducted by the endocardial application of radiofrequency ablation with a temperature-controlled multipolar radiofrequency catheter. LA volume and booster function were quantitatively evaluated by multislice computed tomography at 17.9±10.0 months (MAZE group) and 15.3±13.6 months (CABG group) postoperatively. All patients with MAZE were free of AF and other atrial arrhythmias during the follow-up period. In the CABG group, LA maximal and minimal volumes and ejection fraction were 109±12 mL, 82±11 mL, and 26±10%, respectively. In the MAZE group, LA maximal volume was 139±17 mL ( P =0.187 versus CABG), and LA minimal volume was 121±16 mL ( P =0.082 versus CABG), with an ejection fraction of 15±7% ( P =0.004 versus CABG). In both groups, all parts of the LA wall contracted toward the geometric center of the LA. The extent of wall motion was significantly worse in the MAZE group compared with the CABG group. In both groups, LA booster function was inversely correlated with LA maximal volume. Conclusions— MAZE with radiofrequency ablation is safe and effective for the restoration of sinus rhythm in patients with chronic AF and mitral valve disease. However, chronic AF associated with mitral valve disease deteriorates LA mechanical function diffusely throughout the LA wall. Further studies with the use of multislice computed tomography are needed to sequentially evaluate LA function after MAZE in patients with and without mitral valve surgery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 35 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3