Maximizing Survival Benefit With Primary Prevention Implantable Cardioverter-Defibrillator Therapy in a Heart Failure Population

Author:

Levy Wayne C.1,Lee Kerry L.1,Hellkamp Anne S.1,Poole Jeanne E.1,Mozaffarian Dariush1,Linker David T.1,Maggioni Aldo P.1,Anand Inder1,Poole-Wilson Philip A.1,Fishbein Daniel P.1,Johnson George1,Anderson Jill1,Mark Daniel B.1,Bardy Gust H.1

Affiliation:

1. From the University of Washington, Seattle (W.C.L., J.E.P., D.T.L., D.P.F.); Duke University Medical Center and Duke Clinical Research Institute, Durham, NC (K.L.L., A.S.H., D.B.M.); Harvard Medical School, Boston, Mass (D.M.); Italian Association of Hospital Cardiologists, Florence, Italy (A.P.M.); University of Minnesota, Minneapolis (I.A.); Imperial College School of Medicine, London, UK (P.A.P.-W.); and Seattle Institute of Cardiology Research, Seattle, Wash (G.J., J.A., G.H.B.).

Abstract

Background— Although implantable cardioverter-defibrillator (ICD) therapy reduces mortality in moderately symptomatic heart failure patients with an ejection fraction ≤35%, many such patients do not require ICD shocks over long-term follow-up. Methods and Results— Using a modification of a previously validated risk prediction model based on routine clinical variables, we examined the relationship between baseline predicted mortality risk and the relative and absolute survival benefits of ICD treatment in the primary prevention Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT). In the placebo arm, predicted 4-year mortality grouped into 5 equal-sized risk groups varied from 12% to 50% (c statistic=0.71), whereas the proportion of SCD in those same risk groups decreased from 52% to 24% of all deaths. ICD treatment decreased relative risk of SCD by 88% in the lowest-risk group versus 24% in the highest-risk group ( P =0.009 for interaction) and decreased relative risk of total mortality by 54% in the lowest-risk group versus no benefit (2%) in the highest-risk group ( P =0.014 for interaction). Absolute 4-year mortality reductions were 6.6%, 8.8%, 10.6%, 14.0%, and −4.9% across risk quintiles. In highest-risk patients (predicted annual mortality >20%), no benefit of ICD treatment was seen. Projected over each patient’s predicted lifespan, ICD treatment added 6.3, 4.1, 3.0, 1.9, and 0.2 additional years of life in the lowest- to highest-risk groups, respectively. Conclusions— A clinical risk prediction model identified subsets of moderately symptomatic heart failure patients in SCD-HeFT in whom single-lead ICD therapy was of no benefit and other subsets in which benefit was substantial.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3