Comparison of Plaque Sealing With Paclitaxel-Eluting Stents Versus Medical Therapy for the Treatment of Moderate Nonsignificant Saphenous Vein Graft Lesions

Author:

Rodés-Cabau Josep1,Bertrand Olivier F.1,Larose Eric1,Déry Jean-Pierre1,Rinfret Stéphane1,Bagur Rodrigo1,Proulx Guy1,Nguyen Can M.1,Côté Mélanie1,Landcop Marie-Claude1,Boudreault Jean-Rock1,Rouleau Jacques1,Roy Louis1,Gleeton Onil1,Barbeau Gérald1,Noël Bernard1,Courtis Javier1,Dagenais Gilles R.1,Després Jean-Pierre1,DeLarochellière Robert1

Affiliation:

1. From the Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec, Québec, Canada.

Abstract

Background— The presence of moderate saphenous vein graft (SVG) lesions is a major predictor of cardiac events late after coronary artery bypass grafting. We determined the effects of sealing moderate nonsignificant SVG lesions with paclitaxel-eluting stents (PES) on the prevention of SVG atherosclerosis progression. Methods and Results— Patients with at least 1 moderate SVG lesion (30% to 60% diameter stenosis) were randomized either to stenting the moderate SVG lesion with a PES (n=30, PES group) or to medical treatment alone (n=27, medical treatment group). Patients had an angiographic and intravascular ultrasound evaluation of the SVG at baseline and at 12-month follow-up. The primary end points were (1) the ultrasound SVG minimal lumen area at follow-up and (2) the changes in ultrasound atheroma volume in an angiographically nondiseased SVG segment. Mean time from coronary artery bypass grafting was 12±6 years, and mean low-density lipoprotein cholesterol level was 73±31 mg/dL. A total of 70 moderate SVG lesions (39±7% diameter stenosis) were evaluated. Significant disease progression occurred in the medical treatment group at the level of the moderate SVG lesion (decrease in minimal lumen area from 6.3±3.0 to 5.6±3.1 mm 2 ; P <0.001), leading to a severe flow-limiting lesion or SVG occlusion in 22% of the patients compared with none in the PES group ( P =0.014). In the PES group, mean minimal lumen area increased ( P <0.001) from 6.1±2.2 to 8.6±2.9 mm 2 at follow-up ( P =0.001 compared with the medical treatment group at 12 months). There were no cases of restenosis or stent thrombosis. No significant atherosclerosis progression occurred at the nonstented SVG segments. At 12-month follow-up, the cumulative incidence of major adverse cardiac events related to the target SVG was 19% in the medical treatment group versus 3% in the PES group ( P =0.091). Conclusions— Stenting moderate nonsignificant lesions in old SVGs with PES was associated with a lower rate of SVG disease progression and a trend toward a lower incidence of major adverse cardiac events at 1-year follow-up compared with medical treatment alone, despite very low low-density lipoprotein cholesterol values. This pilot study supports further investigation into the role of plaque sealing in SVGs. Clinical Trial Registration— URL: http://www.clinicaltrials.gov. Unique identifier: NCT002289835.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3