Comparison Between Patent Ductus Arteriosus Stent and Modified Blalock-Taussig Shunt as Palliation for Infants With Ductal-Dependent Pulmonary Blood Flow

Author:

Glatz Andrew C.1,Petit Christopher J.2,Goldstein Bryan H.3,Kelleman Michael S.2,McCracken Courtney E.1,McDonnell Alicia1,Buckey Timothy1,Mascio Christopher E.2,Shashidharan Subi2,Ligon R. Allen2,Ao Jingning2,Whiteside Wendy3,Wallen W. Jack3,Metcalf Christina M.3,Aggarwal Varun4,Agrawal Hitesh4,Qureshi Athar M.4

Affiliation:

1. Cardiac Center at the Children’s Hospital of Philadelphia, University of Pennsylvania School of Medicine (A.C.G., A.M., T.B., C.E.M.)

2. Children’s Healthcare of Atlanta, Emory University School of Medicine, GA (C.J.P., M.S.K., C.E.M., S.S., R.A.L., J.A.)

3. Heart Institute, Cincinnati Children’s Hospital Medical Center, University of Cincinnati College of Medicine, OH (B.H.G., W.W., W.J.W., C.M.M.)

4. Lillie Frank Abercrombie Section of Cardiology, Texas Children’s Hospital, Baylor College of Medicine, Houston (V.A., H.A., A.M.Q.)

Abstract

Background: Infants with ductal-dependent pulmonary blood flow may undergo palliation with either a patent ductus arteriosus (PDA) stent or a modified Blalock-Taussig (BT) shunt. A balanced multicenter comparison of these 2 approaches is lacking. Methods: Infants with ductal-dependent pulmonary blood flow palliated with either a PDA stent or a BT shunt from January 2008 to November 2015 were reviewed from the 4 member centers of the Congenital Catheterization Research Collaborative. Outcomes were compared by use of propensity score adjustment to account for baseline differences between groups. Results: One hundred six patients with a PDA stent and 251 patients with a BT shunt were included. The groups differed in underlying anatomy (expected 2-ventricle circulation in 60% of PDA stents versus 45% of BT shunts; P =0.001) and presence of antegrade pulmonary blood flow (61% of PDA stents versus 38% of BT shunts; P <0.001). After propensity score adjustment, there was no difference in the hazard of the primary composite outcome of death or unplanned reintervention to treat cyanosis (hazard ratio, 0.8; 95% confidence interval [CI], 0.52–1.23; P =0.31). Other reinterventions were more common in the PDA stent group (hazard ratio, 29.8; 95% CI, 9.8–91.1; P <0.001). However, the PDA stent group had a lower adjusted intensive care unit length of stay (5.3 days [95% CI, 4.2–6.7] versus 9.19 days [95% CI, 7.9–10.6]; P <0.001), a lower risk of diuretic use at discharge (odds ratio, 0.4; 95% CI, 0.25–0.64; P <0.001) and procedural complications (odds ratio, 0.4; 95% CI, 0.2–0.77; P =0.006), and larger (152 mm 2 /m 2 [95% CI, 132–176] versus 125 mm 2 /m 2 [95% CI, 113–138]; P =0.029) and more symmetrical (symmetry index, 0.84 [95% CI, 0.8–0.89] versus 0.77 [95% CI, 0.75–0.8]; P =0.008] pulmonary arteries at the time of subsequent surgical repair or last follow-up. Conclusions: In this multicenter comparison of palliative PDA stent and BT shunt for infants with ductal-dependent pulmonary blood flow adjusted for differences in patient factors, there was no difference in the primary end point, death or unplanned reintervention to treat cyanosis. However, other markers of morbidity and pulmonary artery size favored the PDA stent group, supporting PDA stent as a reasonable alternative to BT shunt in select patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3