Detection of Left Atrial Myopathy Using Artificial Intelligence–Enabled Electrocardiography

Author:

Verbrugge Frederik H.12ORCID,Reddy Yogesh N.V.1,Attia Zachi I.1ORCID,Friedman Paul A.1,Noseworthy Peter A.1ORCID,Lopez-Jimenez Francisco1ORCID,Kapa Suraj1ORCID,Borlaug Barry A.1ORCID

Affiliation:

1. Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (F.H.V., Y.N.V.R., Z.I.A., P.A.F., P.A.N., F.L.-J., S.K., B.A.B.).

2. Biomedical Research Institute, Faculty of Medicine and Life Sciences, Hasselt University, Belgium (F.H.V.).

Abstract

Background: Left atrial (LA) myopathy is common in patients with heart failure and preserved ejection fraction and leads to the development of atrial fibrillation (AF). We investigated whether the likelihood of LA remodeling, LA dysfunction, altered hemodynamics, and risk for incident AF could be identified from a single 12-lead ECG using a novel artificial intelligence (AI)-enabled ECG analysis. Methods: Patients with heart failure and preserved ejection fraction (n=613) underwent AI-enabled ECG analysis, echocardiography, and cardiac catheterization. Individuals were grouped by AI-enabled ECG probability of contemporaneous AF, taken as an indicator of underlying LA myopathy. Results: Structural heart disease was more severe in patients with higher AI-probability of AF, with more left ventricular hypertrophy, larger LA volumes, and lower LA reservoir and booster strain. Cardiac filling pressures and pulmonary artery pressures were higher in patients with higher AI-probability, while cardiac output reserve was more impaired during exercise. Among patients with sinus rhythm and no prior AF, each 10% increase in AI-probability was associated with a 31% greater risk of developing new-onset AF (hazard ratio, 1.31 [95% CI, 1.20–1.42]; P <0.001). In the population as a whole, each 10% increase in AI-probability was associated with a 12% greater risk of death (hazard ratio, 1.12 [95% CI, 1.08–1.17]; P <0.001) during long-term follow-up, which was no longer significant after adjustments for baseline characteristics. Conclusions: A novel AI-enabled score derived from a single 12-lead ECG identifies the presence of underlying LA myopathy in patients with heart failure and preserved ejection fraction as evidenced by structural, functional, and hemodynamic abnormalities, as well as long-term risk for incident AF. Further research is required to determine the role of the AI-enabled ECG in the evaluation and care of patients with heart failure and preserved ejection fraction.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3