Bridge-to-Decision Therapy With a Continuous-Flow External Ventricular Assist Device in Refractory Cardiogenic Shock of Various Causes

Author:

Takayama Hiroo1,Soni Lori1,Kalesan Bindu1,Truby Lauren K.1,Ota Takeyoshi1,Cedola Sophia1,Khalpey Zain1,Uriel Nir1,Colombo Paolo1,Mancini Donna M.1,Jorde Ulrich P.1,Naka Yoshifumi1

Affiliation:

1. From the Departments of Surgery (H.T., L.S., B.K., L.K.T., T.O., S.C., Z.K., Y.N.) and Medicine (N.U., P.C., D.M.M., U.P.J.), Columbia University Medical Center, New York, NY.

Abstract

Background— Mortality for refractory cardiogenic shock remains high. In this patient cohort, there have been mixed results in mechanical circulatory support device use as a bridge-to-decision therapy. We evaluated a continuous-flow external ventricular assist device (VAD), CentriMag VAD (Thoratec Corp., Pleasanton, CA), in patients with various causes of refractory cardiogenic shock. Methods and Results— This is a retrospective review of adult patients who underwent surgical CentriMag VAD insertion as bridge-to-decision therapy. From January 2007 through June 2012, 143 patients received CentriMag VAD. The cause of refractory cardiogenic shock was failure of medical management in 71 patients, postcardiotomy shock in 37, graft failure post–heart transplantation in 22, and right ventricular failure post–implantable left VAD in 13. Mean age was 52±16 years, and 71% were in INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) profile 1. Among 158 device runs, device configuration was BiVAD in 67%, isolated right VAD in 26%, and isolated left VAD in 8%. Median duration of support was 14 days (interquartile range, 8–26). Survival was 69% at 30 days and 49% at 1 year. The next destination after the CentriMag VAD was myocardial recovery in 30%, device exchange to an implantable VAD in 15%, and heart transplantation in 18%. The failure of medical management and the graft failure post–heart transplantation groups had higher 30-day survival compared with the postcardiotomy shock group. Major bleeding events occurred in 33% and cerebrovascular accidents in 14%. There was no CentriMag pump failure or thrombosis. Conclusions— Bridge-to-decision therapy with CentriMag VAD is feasible in a variety of refractory cardiogenic shock settings. Patients with postcardiotomy shock have inferior survival.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 99 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3