1. From the RHJ Department of Veterans Affairs Medical Center, Medical University of South Carolina, Charleston (M.R.Z., S.E.H., C.F.B.); Medtronic, Inc, Minneapolis, MN (T.D.B., F.J.K.); The Ohio State University, Columbus (W.T.A.), University of Alabama at Birmingham (R.C.B.); and Brigham and Women’s Hospital, Boston, MA (L.S.).

Abstract

Background— The purpose of this analysis was to examine whether implantable hemodynamic monitor–derived baseline estimated pulmonary artery diastolic pressure (ePAD) and change from baseline ePAD were independent predictors of all-cause mortality in patients with chronic heart failure. Methods and Results— Retrospective analysis used data from 3 studies (n=790 patients; 216 deaths). Baseline ePAD was related to mortality using a multivariable model including baseline and demographic data. Changes in ePAD defined as change from baseline to 6 months and from baseline to 14 days before death or exit from study were related to subsequent mortality, and analysis was adjusted for baseline ePAD. Area under the pressure versus time curve during 180 days before death or exit from study was related to mortality. Baseline ePAD, independent of other covariates, was a significant predictor of mortality (hazard ratio=1.07; 95% confidence interval=1.05–1.09; P <0.0001). Change in ePAD was an independent predictor of mortality (hazard ratio=1.07; 95% confidence interval=1.05–1.100; P =0.0008). Increased ePAD of 3, 4, or 5 mm Hg from baseline to 6 months was associated with increased mortality risk of 23.8%, 32.9%, or 42.8%. Change in ePAD from baseline to 14 days before death or exit from study was higher in patients who died (3.0±8 versus 1.7±10 mm Hg; P =0.003). Area under the pressure versus time curve in the final 180 days before death or exit from study was higher in patients who died versus those alive at end of study (185±668 versus 17±482 mm Hg.days; P =0.006). Conclusions— Implantable hemodynamic monitor–derived baseline ePAD and change from baseline ePAD were independent predictors of mortality in chronic heart failure patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 86 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3