Pulse Wave Analysis of the Aortic Pressure Waveform in Severe Left Ventricular Systolic Dysfunction

Author:

Denardo Scott J.1,Nandyala Ramavathi1,Freeman Gregory L.1,Pierce Gary L.1,Nichols Wilmer W.1

Affiliation:

1. From the University of Florida (S.J.D., W.W.N.) and Department of Veterans Affairs Medical Center (S.J.D.), Gainesville, Fla; University of Texas Health Science Center (R.N., G.L.F.), San Antonio, Tex; and University of Colorado (G.L.P.), Boulder, Colo.

Abstract

Background— The effect of moderate left ventricular systolic dysfunction (LVSD) on ventricular/vascular coupling and the aortic pressure waveform (AoPW) has been well described, but the effect of severe LVSD has not. Methods and Results— We used noninvasive, high-fidelity tonometry of the radial artery and a mathematical transfer function to generate the AoPW in 25 treated patients with LVSD (mean LV ejection fraction, 24±8.8%; range, 11% to 40%; 21 patients <30%). Pulse wave analysis of the AoPW was used to characterize ventricular/vascular coupling and compared with pulse wave analysis performed in 25 normal subjects matched for age, gender, height, body mass index, and heart rate. Measurements obtained using pulse wave analysis in LVSD patients indicated features of poor LV stroke performance and also reduced indices of arterial stiffness: increased travel time of the pressure wave (147±10 ms versus 132±21 ms; P <0.001); decreased systolic duration of reflected wave (134±24 ms versus 167±26 ms; P <0.001); ejection duration (277±22 ms versus 299±25 ms; P <0.008); percent systolic duration (32±5.3% versus 35±4.0%; P <0.02); aortic systolic pressure (100±16 mm Hg versus 121±16 mm Hg; P <0.001); unaugmented pressure (24±6.3 mm Hg versus 32±6.4 mm Hg; P <0.001); augmented pressure (4.8±3.1 mm Hg versus 9.6±4.5 mm Hg; P <0.001); pulse pressure (28±7.4 mm Hg versus 42±9.5 mm Hg; P <0.001); augmentation index (12±6.6% versus 23±7.6%; P <0.006); wasted LV effort (5.3±2.8×10 2 dyne sec/cm 2 versus 17±10×10 2 dyne sec/cm 2 ; P <0.001); systolic pressure time index (17±4.1×10 2 mm Hg-sec/min versus 23±4.2×10 2 mm Hg sec/min; P <0.001); and pressure systolic area (383±121 mm Hg sec/min versus 666±150 mm Hg sec/min; P <0.001). Conclusions— Severe LVSD causes measurable changes in the AoPW. Standardization of AoPW findings in LVSD patients may allow for the clinical use of radial artery pulse wave analysis to noninvasively determine the severity of dysfunction and aid in logical therapy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Reference47 articles.

1. Forward and backward waves in the arterial system

2. Time domain analysis of the arterial pulse in clinical medicine

3. Nichols WW O'Rourke MF. McDonald’s Blood Flow in Arteries: Theoretic Experimental and Clinical Principles. 5th ed. London: Edward Arnold; 2005.

4. Noninvasive Pulse Waveform Analysis in Clinical Trials: Similarity of Two Methods for Calculating Aortic Systolic Pressure

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3