Abstract WMP16: Artificial Intelligence Detection of Cerebrovascular Large Vessel Occlusion - Nine Month, 650 Patient Evaluation of the Diagnostic Accuracy and Performance of the Viz.ai LVO Algorithm

Author:

Chatterjee Arindam1,Somayaji Nayana R2,Kabakis Ismail M1

Affiliation:

1. Med Univ of South Carolina, Charleston, SC

2. Radiology, Med Univ of South Carolina, Charleston, SC

Abstract

Introduction: Prompt and accurate identification of Large Vessel Occlusion (LVO) for Acute Ischemic Stroke (AIS) by CTA is essential for optimal endovascular reperfusion therapy. The Viz.ai algorithm (Viz LVO) was developed to process head and neck CTAs using a convolutional neural network artificial intelligence platform to identify anterior circulation LVOs from the ICA-T to the sylvian MCA M1 segments. We evaluated the diagnostic accuracy and notification time of Viz LVO compared with our institutional standard of care. Methods: Consecutively acquired CTAs performed for suspected AIS between 3/1/2016 and 11/30/2017 were identified for inclusion. No studies were excluded from analysis to reflect our institutional prevalence of anterior circulation LVOs. The CTAs were evaluated by the Viz-AI-Algorithm® v4.1.2. The processing time and automated LVO detection were recorded. These were compared against the radiology report, the radiologist to stroke care team time-to-notification, as well as an independent review of all studies by a neuroradiologist for secondary findings that may influence the accuracy of Viz LVO. Results: Analysis of 650 CTAs performed for AIS was conducted for 650 patients. The mean patient age was 66 (SD 15), 51% were female, and 30% of all studies were positive for anterior circulation LVO. Viz.ai demonstrated a sensitivity of 82%, specificity of 94%, PPV of 77%, and NPV of 95%. There were 31 false positives (16 due to intracranial atherosclerosis) and 23 false negatives reported by Viz.ai. Forty one cases were not processed due to metal artifact, inadequate contrast, motion artifact, or excess z-spacing variability. The mean processing time for Viz.ai was 5 minutes with a maximum of 8 minutes for all studies. The mean clinical standard-of-care notification time at our institution was 32 minutes with a maximum of 116 minutes. Conclusion: To the best of our knowledge, this is the first AI-algorithm for detecting intracranial LVOs. Viz LVO has demonstrated impressive performance for accurate identification and timely notification of proximal intracranial LVOs. Future endeavors to optimize detection of LVO in poor quality CTAs, despite anatomic variations such as tortuosity, and of the MCA-M2 are ongoing.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3