Long-term Reproducibility of Ventricular Tachycardia Induction in Patients With Implantable Cardioverter/Defibrillators

Author:

Gillis Anne M.1,Sheldon Robert S.1,Wyse D. George1,Leitch James W.1,Yee Raymond1,Klein George J.1,Duff Henry J.1,Mitchell L. Brent1

Affiliation:

1. From the Departments of Medicine, Foothills Medical Centre and The University of Calgary, Alberta, and University Hospital and the University of Western Ontario, London, Ontario, Canada.

Abstract

Background Noninvasive electrophysiological studies (EPSs) can be performed in current implantable antitachycardia pacemaker/cardioverter/defibrillators (ICDs). Thus, these devices may be used as tools to study changes in the electrophysiological substrate and ventricular tachycardia characteristics over time. Methods and Results Fifty-five patients receiving an ICD for treatment of sustained ventricular tachyarrhythmias underwent serial EPSs after implantation of the ICD. Studies were performed before hospital discharge and 1, 3, 5, 9, 12, 18, 24, and 36 months after ICD implantation. Sustained monomorphic ventricular tachycardia (VT) was induced in 37 patients (group 1) at the predischarge EPS, whereas no sustained arrhythmia could be induced in 18 patients (group 2) at baseline. Group 1 patients underwent 165 noninvasive EPSs after discharge. Sustained monomorphic VT was induced during 72% of the follow-up EPSs, ventricular fibrillation (VF) was induced during 11% of follow-up EPSs, and no sustained VT or VF was induced during 17% of follow-up visits. Sustained VT was induced at every follow-up EPS in 23 patients (62%), whereas no sustained VT/VF could be induced at least once during follow-up in 14 patients (38%). Clinical or electrophysiological variables did not predict noninducibility during follow-up. However, the probability that a patient would experience spontaneous VT decreased significantly over time in patients in whom VT was not inducible during at least 1 follow-up EPS ( P =.05). Group 2 patients underwent 86 noninvasive EPSs after discharge. Sustained monomorphic VT was induced during 22% of follow-up EPSs, VF was induced during 19% of follow-up EPSs, and no sustained VT/VF could be induced during 68% of follow-up EPSs. No sustained VT/VF could be induced during every follow-up EPS in 9 patients (50%), whereas sustained monomorphic VT was induced at least once during follow-up in 7 patients (34%). Persistent noninducibility of VT during follow-up was associated with low probability of occurrence of spontaneous VT (11%), whereas inducibility of VT at least once during follow-up was associated with the occurrence of spontaneous VT (89%, P =.003). Conclusions Considerable variability of VT induction is observed over a lengthy period in patients presenting with sustained VT/VF. Persistent noninducibility of VT is associated with a reduced probability of spontaneous VT. These observations suggest that the substrates for inducible and spontaneous VT change in parallel over time.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3