Weaning From Mechanical Cardiac Support in Patients With Idiopathic Dilated Cardiomyopathy

Author:

Müller Johannes1,Wallukat Gerd1,Weng Yu-Guo1,Dandel Michael1,Spiegelsberger Susanne1,Semrau Sabine1,Brandes Kersten1,Theodoridis Vassilis1,Loebe Matthias1,Meyer Rudolf1,Hetzer Roland1

Affiliation:

1. From the German Heart Institute Berlin, Department of Cardiac and Vascular Surgery, and the Max-Delbrück-Center, Berlin, Germany (G.W.).

Abstract

Background Implantation of mechanical cardiac support systems (MCSS) in patients with idiopathic dilated cardiomyopathy (IDC) may improve cardiac function and allow explantation of the device. We report of long-term effects of ventricular unloading on cardiac function, humoral anti-β1-adrenoceptor autoantibodies (A-β 1 -AABs), and myocardial fibrosis. Methods and Results Seventeen patients in New York Heart Association functional class IV with nonischemic IDC received MCSS. All had a cardiac index of <1.6 L · min −1 · m −2 of body surface area, a left ventricular ejection fraction (LVEF) of <16%, and a left ventricular internal diameter in diastole (LVIDd) of >68 mm and tested positive for A-β 1 -AABs. Echocardiographic evaluation, serum tests for A-β 1 -AABs, and histological assessment of myocardial fibrosis were performed before and after MCSS implantation. The mean support duration was 230±201 days. Six patients died, four were transplanted, and two are still on MCSS. Five patients with significant cardiac recovery (mean LVIDd, 54±2.3 mm; LVEF, 47±3.7%) were weaned after 160 to 794 days and are now device free for 51 to 592 days. A-β 1 -AABs disappeared gradually during MCSS without increase after weaning; cardiac function and volume density of fibrosis remained normal. Nine patients’ cardiac function hardly improved during ventricular unloading. Conclusions Cardiac function can be normalized in selected patients with end-stage IDC by MCSS. The degree of preoperative myocardial fibrosis may be an indicator for outcome; A-β 1 -AABs can be used to monitor myocyte recovery. Weaning from MCSS offers an alternative to cardiac transplantation in certain patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 250 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3