Permanent Pacemaker Selection and Subsequent Survival in Elderly Medicare Pacemaker Recipients

Author:

Lamas Gervasio A.1,Pashos Chris L.1,Normand Sharon-Lise T.1,McNeil Barbara1

Affiliation:

1. From the Division of Cardiology, Mount Sinai Medical Center, Miami Beach, and the University of Miami School of Medicine (G.A.L.), Miami, Fla; Cardiovascular Division (G.A.L.), Brigham and Women’s Hospital, and the Department of Health Care Policy (C.L.P., S.T.N., B.M.), Harvard Medical School, Boston, Mass.

Abstract

Background Dual-chamber pacemakers have been in use for more than 15 years. Although they may confer a physiological advantage over single-chamber ventricular pacemakers, they are more expensive and have a generally shorter service life than single-chamber devices. We carried out the present study to identify patient subgroups who were preferentially receiving greater or lesser proportions of dual-chamber devices and to determine whether the selection of different types of pacemakers was associated with differences in mortality. Methods and Results We analyzed a 20% random national sample of all Medicare beneficiaries aged 65 years or older who underwent initial placement of a permanent pacemaker and were discharged in 1988, 1989, or 1990 (n=36 312). The minimum follow-up for vital status was 1 year. The relation of pacemaker type to patient and provider characteristics was determined using logistic regression analysis. The relation between pacemaker type and mortality was determined using the Cox proportional hazards method. The proportion of dual-chamber systems that were received increased from 27.2% in 1988 to 37.0% in 1990 ( P <.001). Dual-chamber pacemaker recipients were younger ( P <.001) than ventricular pacemaker recipients. Other independent correlates of dual-chamber pacemaker selection included male sex (odds ratio and 95% confidence intervals, 1.18 and 1.12 to 1.24, respectively), atrioventricular block (1.59 and 1.51 to 1.67), congestive heart failure (1.14 and 1.08 to 1.20), atrial fibrillation (0.36 and 0.34 to 0.39), and the presence of a major noncardiac diagnosis (0.86 and 0.83 to 0.89). Nonmedical predictors of dual-chamber pacemaker selection included Medicaid eligibility (0.78 and 0.71 to 0.86), implantation in the western United States (1.19 and 1.10 to 1.29), implantation by a rural provider (0.70 and 0.65 to 0.76), hospitalization in a 500-bed-or-larger hospital (1.20 and 1.13 to 1.28), hospitalization in a private hospital (1.19 and 1.10 to 1.28), or hospitalization in a hospital with a catheterization laboratory (1.47 and 1.38 to 1.56). Dual-chamber pacemaker selection was an independent predictor of survival at 1 year (0.82 and 0.77 to 0.87) and at 2 years (0.82 and 0.77 to 0.87) after controlling for potentially confounding patient-level and hospital-level characteristics. Conclusions The present study describes important variations in the clinical practice of cardiac pacing, many of which are not based on clinical characteristics. Furthermore, the selection of a dual-chamber pacemaker is associated with increased survival. These results underscore the need for prospective, outcome-based clinical trials of pacemaker mode selection.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 116 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3