Pulmonary and Left Ventricular Decompression by Artificial Pulmonary Valve Incompetence During Percutaneous Cardiopulmonary Bypass Support in Cardiac Arrest

Author:

Scholz Karl H.1,Figulla Hans R.1,Schröder Thomas1,Hering Jens P.1,Bock Herbert1,Ferrari Marcus1,Kreuzer Heinrich1,Hellige Gerhard1

Affiliation:

1. From the Department of Cardiology (K.H.S., H.R.F., H.K.), Department of Anesthesiology (T.S., J.P.H., M.F., G.H.), and Department of Cardiothoracic Surgery (H.B.), Georg-August University of Göttingen, Germany.

Abstract

Background In cardiac arrest, use of percutaneous cardiopulmonary bypass support (PCPS) may lead to left ventricular loading, with deleterious effects on the myocardium, and is often accompanied by an increase in pulmonary artery pressure. The present study was designed to assess the potential of artificially induced pulmonary valve incompetency to retrogradely decompress the left ventricle during PCPS in ventricular fibrillation. Methods and Results Studies were performed using a standardized experimental animal model in sheep (n=12; body weight, 77 to 112 kg). When PCPS was used during fibrillation, an increase in left ventricular pressure (from 21.4±5.0 mm Hg after 1 minute to 28.4±9.5 mm Hg after 10 minutes of fibrillation) was observed in all animals, with a simultaneous increase in pulmonary artery pressure in 6 animals from 15.5± 3.8 to 24.3±5.4 mm Hg (group A). In these animals, artificial pulmonary valve incompetency, which was induced by a special “pulmonary valve spreading catheter,” led to effective decompression of both the pulmonary circulation (decrease in pulmonary artery pressure from 24.3 to 11.3 mm Hg) and the left ventricle (decrease in left ventricular pressure from 30.5 to 17.7 mm Hg). We simultaneously measured a decrease in the myocardial release of lactate (increase in arterial coronary-venous difference in lactate content from −0.01 to 0.14 mmol/L), demonstrating the myocardial protective effect of the procedure. In contrast, in 6 animals without an increase in pulmonary artery pressure during PCPS (group B), artificial pulmonary valve incompetency did not reduce left ventricular loading, which was probably because of competent mitral valves in these animals. Conclusions In case of increasing pulmonary artery pressure during PCPS in cardiac arrest, artificial pulmonary valve incompetency might be a useful tool for effective pulmonary and retrograde left ventricular decompression.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3