Ultrasound guidance of Palmaz-Schatz intracoronary stenting with a combined intravascular ultrasound balloon catheter.

Author:

Mudra H1,Klauss V1,Blasini R1,Kroetz M1,Rieber J1,Regar E1,Theisen K1

Affiliation:

1. Department of Medicine, Klinikum Innenstadt, University of Munich, Germany.

Abstract

BACKGROUND Coronary stenting in conjunction with coronary angioplasty is a valuable tool for treatment of severe coronary dissection and is effective in reducing the frequency of restenoses. Evidence is increasing that the lumen gain within the stent is negatively correlated with the rate of subacute closures and restenoses. Since the assessment of radiolucent coronary stents and complex lumen morphologies by angiography is limited, we hypothesized that the use of a balloon catheter with integrated intravascular ultrasound (IVUS) facility for stent deployment and guidance of its expansion could improve the acute lumen gain without relevant procedural prolongation. METHODS AND RESULTS Deployment of a single Palmaz-Schatz coronary stent with the combined imaging balloon catheter alone was successful in 18 of 20 patients eligible for this study. Corresponding measurements of minimal lumen diameter (MLD) by angiography and IVUS could be performed in 16 patients, revealing a close correlation between the two methods within the reference segments (3.10 +/- 0.38 and 3.08 +/- 0.43 mm, r = .79). Despite an adequate angiographic result in most patients after stent deployment, IVUS showed smaller MLD within the stented segment (2.15 +/- 0.23 mm) compared with angiography (2.63 +/- 0.26 mm, P < .0001) with a poor correlation (r = .27). To achieve IVUS criteria for optimal stent expansion (ratio of 0.9 between IVUS-assessed cross-sectional area of stent and reference segment), an average of three additional balloon inflations with higher pressure and/or a larger balloon diameter were performed without adverse effects in 15 of 16 patients who initially did not fulfill these criteria. This resulted in a significant increase in stent MLD to 2.63 +/- 0.27 mm (IVUS, P < .0001 versus initial MLD) and 2.89 +/- 0.32 mm (angiography, P < .0002 versus initial MLD) and a better correlation between the two methods (r = .60). The IVUS guidance led to a 40 +/- 15% increase of the minimal stent cross-sectional area with an additional time consumption of 21 minutes on average. CONCLUSIONS This study demonstrates the application of a combined imaging balloon catheter for delivery and ultrasound-guided expansion of Palmaz-Schatz coronary stents. IVUS offered a comprehensive insight into the stented coronary segments, revealing a substantial overestimation of stent dimensions by angiography. IVUS guidance led to a significant improvement of stent expansion. This additional lumen gain, which was not discernible by angiography in most patients, might result in a reduction of subacute stent thromboses as well as restenoses.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3