Relation of Mean Right Atrial Pressure to Echocardiographic and Doppler Parameters of Right Atrial and Right Ventricular Function

Author:

Nagueh Sherif F.1,Kopelen Helen A.1,Zoghbi William A.1

Affiliation:

1. From the Section of Cardiology, Department of Medicine, Baylor College of Medicine and The Methodist Hospital, Echocardiography Laboratory, Houston, Tex.

Abstract

Background A paucity of data exists as to the relation of mean right atrial pressure (RAP) to Doppler parameters of right atrial and ventricular filling. Furthermore, whether echocardiographic parameters of right atrial and right ventricular function and inferior vena cava improve the relation of Doppler filling dynamics with RAP has not been explored. Methods and Results Doppler and echocardiographic studies were performed simultaneously with measurements of mean RAP in consecutive patients who either had a central venous catheter in the Intensive Care Unit or underwent catheterization of the right side of the heart. The initial population consisted of 35 patients with a mean age (±SD) of 60±15 years; 34% were on mechanical ventilation. Mean RAP averaged 9±5.7 mm Hg (range, 2 to 28 mm Hg). Among tricuspid inflow parameters, the strongest relation with RAP was observed with the ratio of early to late velocity ( r =.66). For hepatic venous flow, systolic filling wave indexes had the best relation with atrial pressure, the highest being for systolic filling fraction ( r =−.86). Weaker relations were noted with the use of right atrial volumes, right ventricular function, and inferior vena caval diameters. The addition of any of these variables did not improve the relation of systolic filling fraction with RAP. The regression equation (RAP=21.6−24 systolic filling fraction) was tested prospectively in the estimation of atrial pressure in 50 patients. The correlation coefficient was .89 in the prospective group and .88 in the total group of 85 patients. The mean difference between predicted and actual pressures in the whole population was −0.2±2.6 mm Hg. The sensitivity and specificity for mean RAP>8 mm Hg were 86% and 92%, respectively. Conclusions Among echocardiographic and Doppler parameters of right atrial and right ventricular function, hepatic venous flow dynamics relate best to mean atrial pressure and can be used clinically to estimate mean RAP.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3