Prediction of Restenosis After Coronary Balloon Angioplasty

Author:

Peters Ron J.G.1,Kok Wouter E.M.1,Di Mario Carlo1,Serruys Patrick W.1,Bär Frits W.H.M.1,Pasterkamp Gerard1,Borst Cornelis1,Kamp Otto1,Bronzwaer Jean G.F.1,Visser Cees A.1,Piek Jan J.1,Panday Radjan N.1,Jaarsma Wiebe1,Savalle Lucas1,Bom Nicolaas1

Affiliation:

1. Interuniversity Cardiology Institute of the Netherlands, Utrecht.

Abstract

Background Intracoronary ultrasound (ICUS) imaging is potentially suitable to identify lesions at high risk of restenosis after percutaneous transluminal coronary angioplasty (PTCA), but it has not been studied systematically. Methods and Results We recruited 200 patients in whom ICUS studies were performed after successful PTCA and related their ICUS parameters to 6-month follow-up quantitative coronary angiography. This was performed in 164 patients (82%), yielding 170 lesions for analysis. The overall incidence of a ≥50% diameter stenosis at follow-up (categorical restenosis) was 29.4%. Quantitative ICUS parameters were weakly but significantly related to follow-up minimal luminal diameter on quantitative coronary angiography (lumen area: R 2 =.36, P =.0001; vessel area: R 2 =.29, P =.0002; plaque area: R 2 =−.18, P =.021; percent obstruction: R 2 =−.15, P =.05), but categorical restenosis was not significantly related to these parameters ( P =.63, .77, .38, and .08, respectively). There were no significant predictors of restenosis in ICUS parameters of plaque morphology: eccentric versus concentric ( P =1.0), plaque type (hard, soft, or calcific, P =.98), or the number of calcified quadrants ( P =.41). There were no significant predictors of restenosis in two predefined types of vessel-wall disruptions: (1) rupture: presence ( P =.79), depth (partial versus complete, P =.85), or extent in quadrants ( P =.6), and (2) dissection: presence ( P =.31), depth ( P =.82), or extent ( P =.38). Conclusions Qualitative ICUS parameters after PTCA did not predict restenosis. A larger lumen and vessel area and a smaller plaque area by ICUS were associated with a larger angiographic minimal lumen diameter at follow-up, but these parameters were not significantly related to categorical restenosis.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3