Body Surface Mapping During Pacing at Multiple Sites in the Human Atrium

Author:

SippensGroenewegen Arne1,Peeters Heidi A. P.1,Jessurun Emile R.1,Linnenbank Andre C.1,Robles de Medina Etienne O.1,Lesh Michael D.1,van Hemel Norbert M.1

Affiliation:

1. From the Section of Cardiac Electrophysiology, Department of Medicine and the Cardiovascular Research Institute (A.S., M.D.L.), University of California at San Francisco; the Department of Cardiology (H.A.P.P., E.O.R.de M.), Heart Lung Institute, University Hospital and State University of Utrecht, the Netherlands; the Department of Cardiology (E.R.J., N.M.van H.), Antonius Hospital, Nieuwegein, the Netherlands; and the Laboratory of Medical Physics (A.C.L.), Academic Medical Center, University of...

Abstract

Background —The morphology and polarity of the P wave on 12-lead ECG are of limited clinical value in localizing ectopic atrial rhythms. It was the aim of this study to assess the spatial resolution of body surface P-wave integral mapping in identifying the site of origin of ectopic right atrial (RA) impulse formation in patients without structural atrial disease. Methods and Results —Sixty-two–lead ECG recordings were obtained during RA pacing at 86 distinct endocardial sites in nine patients with normal biatrial anatomy. After P-wave integral maps were generated for each paced activation sequence, 17 groups with nearly identical map features were visually selected, and a mean P-wave integral map was computed for each group. Supportive statistical analysis to corroborate qualitative group selection was performed by assessment of (1) intragroup pattern uniformity by use of jackknife correlation coefficient analysis of the integral maps contained in each group and (2) intergroup pattern variability by use of the calculation of cross correlations between the 17 mean integral maps. The spatial resolution of paced P-wave body surface mapping in the right atrium was obtained by estimating the area size of endocardial segments with nearly identical P-wave integral maps by use of a biplane fluoroscopic method to compute the three-dimensional position of each pacing site. The latter approach yielded a mean endocardial segment size of 3.5±2.9 cm 2 (range, 0.79 to 10.75 cm 2 ). Conclusions —Use of the P-wave morphology on the 62-lead surface ECG in patients with normal biatrial anatomy allows separation of the origin of ectopic RA impulse formation into one of 17 different endocardial segments with an approximated area size of 3.5 cm 2 . This database of paced P-wave integral maps provides a versatile clinical tool to perform detailed noninvasive localization of right-sided atrial tachycardia before radiofrequency catheter ablation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3